Electrostatic discharge—ESD protectionESD is a major concern when you handle electronic components, especially sensitive components such as expansion cards, processors,memory DIMMs, and system boards. Very slight charges can damage circuits in ways that may not be obvious, such as intermittentproblems or a shortened product life span. As the industry pushes for lower power requirements and increased density, ESD protection isan increasing concern.Due to the increased density of semiconductors used in recent Dell products, the sensitivity to static damage is now higher than inprevious Dell products. For this reason, some previously approved methods of handling parts are no longer applicable.Two recognized types of ESD damage are catastrophic and intermittent failures.• Catastrophic – Catastrophic failures represent approximately 20 percent of ESD-related failures. The damage causes an immediateand complete loss of device functionality. An example of catastrophic failure is a memory DIMM that has received a static shock andimmediately generates a "No POST/No Video" symptom with a beep code emitted for missing or nonfunctional memory.• Intermittent – Intermittent failures represent approximately 80 percent of ESD-related failures. The high rate of intermittent failuresmeans that most of the time when damage occurs, it is not immediately recognizable. The DIMM receives a static shock, but thetracing is merely weakened and does not immediately produce outward symptoms related to the damage. The weakened trace maytake weeks or months to melt, and in the meantime may cause degradation of memory integrity, intermittent memory errors, etc.The more difficult type of damage to recognize and troubleshoot is the intermittent (also called latent or "walking wounded") failure.Perform the following steps to prevent ESD damage:• Use a wired ESD wrist strap that is properly grounded. The use of wireless anti-static straps is no longer allowed; they do not provideadequate protection. Touching the chassis before handling parts does not ensure adequate ESD protection on parts with increasedsensitivity to ESD damage.• Handle all static-sensitive components in a static-safe area. If possible, use anti-static floor pads and workbench pads.• When unpacking a static-sensitive component from its shipping carton, do not remove the component from the anti-static packingmaterial until you are ready to install the component. Before unwrapping the anti-static packaging, ensure that you discharge staticelectricity from your body.• Before transporting a static-sensitive component, place it in an anti-static container or packaging.ESD field service kitThe unmonitored Field Service kit is the most commonly used service kit. Each Field Service kit includes three main components: anti-static mat, wrist strap, and bonding wire.Components of an ESD field service kitThe components of an ESD field service kit are:• Anti-Static Mat – The anti-static mat is dissipative and parts can be placed on it during service procedures. When using an anti-static mat, your wrist strap should be snug and the bonding wire should be connected to the mat and to any bare metal on the systembeing worked on. Once deployed properly, service parts can be removed from the ESD bag and placed directly on the mat. ESD-sensitive items are safe in your hand, on the ESD mat, in the system, or inside a bag.• Wrist Strap and Bonding Wire – The wrist strap and bonding wire can be either directly connected between your wrist and baremetal on the hardware if the ESD mat is not required, or connected to the anti-static mat to protect hardware that is temporarilyplaced on the mat. The physical connection of the wrist strap and bonding wire between your skin, the ESD mat, and the hardware isknown as bonding. Use only Field Service kits with a wrist strap, mat, and bonding wire. Never use wireless wrist straps. Always beaware that the internal wires of a wrist strap are prone to damage from normal wear and tear, and must be checked regularly with awrist strap tester in order to avoid accidental ESD hardware damage. It is recommended to test the wrist strap and bonding wire atleast once per week.• ESD Wrist Strap Tester – The wires inside of an ESD strap are prone to damage over time. When using an unmonitored kit, it is abest practice to regularly test the strap prior to each service call, and at a minimum, test once per week. A wrist strap tester is thebest method for doing this test. If you do not have your own wrist strap tester, check with your regional office to find out if they haveone. To perform the test, plug the wrist-strap's bonding-wire into the tester while it is strapped to your wrist and push the button totest. A green LED is lit if the test is successful; a red LED is lit and an alarm sounds if the test fails.• Insulator Elements – It is critical to keep ESD sensitive devices, such as plastic heat sink casings, away from internal parts that areinsulators and often highly charged.• Working Environment – Before deploying the ESD Field Service kit, assess the situation at the customer location. For example,deploying the kit for a server environment is different than for a desktop or portable environment. Servers are typically installed in arack within a data center; desktops or portables are typically placed on office desks or cubicles. Always look for a large open flat workarea that is free of clutter and large enough to deploy the ESD kit with additional space to accommodate the type of system that is8 Working inside your computer