Table 4. Front panel featuresItem Components Icon Description4 Information tag N/A The Information tag is a slide-out label panel that contains systeminformation such as Service Tag, NIC, MAC address, and so on. If youhave opted for the secure default access to iDRAC, the Information tagalso contains the iDRAC secure default password.5 USB port 2.0 The USB ports are 4-pin, 2.0-compliant. These ports enable you toconnect USB devices to the system.6 USB port 3.0 The USB port is USB 3.0 compliant.7 Optical drive bay N/A Enable you to install drives that are supported on your system.For more information, see the Dell EMC PowerEdge T440 TechnicalSpecifications on the product documentation page.8 Drive slot N/A Enables you to install TBUs for 8x and 16x backplane configurations, ordrive blank in the empty drive slot to maintain proper system cooling.9 Physical drives N/A 3.5-inch drives and 2.5-inch drives/SSDs.Status LED indicatorsNOTE: The indicators display solid amber if any error occurs.Figure 6. Status LED indicatorsTable 5. Status LED indicators and descriptions (continued)Icon Description Condition Corrective actionHealth indicator The indicator turns solid blue if thesystem is in good health. None required.The indicator blinks amber, whenthe system is:● Powered on● In standby● In any error condition Forexample, a failed fan, PSU, ora driveCheck the System event log or system messages forthe specific issue.For more information about error messages, seethe Event and Error Message Reference Guide for14th Generation Dell EMC PowerEdge Servers atwww.dell.com/qrl.The POST process is interrupted without any videooutput due to invalid memory configurations. SeeGetting help.Drive indicator The indicator turns solid amber ifthere is a drive error.● Check the System event log to determine if thedrive has an error.● Run the appropriate Online Diagnostics test.Restart the system, and run embeddeddiagnostics (ePSA.Dell EMC PowerEdge T440 system overview 15