DellPowerEdge T610 Technical Guide 24Maximum ShockOperating Half sine shock in all operational orientations of31 G 5% with a pulse duration of 2.6ms 10%StorageHalf sine shock on all six sides of 71G 5% with apulse duration of 2ms 10% Square wave shock onall six sides of 27G with velocity change @ 235in/sec or greaterAltitudeOperating-16 to 3048m (-50 to 10,000ft) Note: Foraltitudes above 2950 feet, the maximumoperating temperature is de-rated 1°F/550ftStorage -16 to 10,600m (-50 to 35,000ft)For additional information about environmental measurements for specific system configurations, seewww.dell.com/environmental_datasheets.5.6 Power Consumption TestingFeature Energy Smart PowerSupplyHigh Output Power SupplyDimensions L-206.4mm1 x W-67.5mm x H-76.5mmStatus Indicators 1 x bi-color Light Emitting DiodeIntegrated Fans 1 x 60mmFixed Input PlugIEC-C14AC Cord Rating 15 Amps @ 120 VAC, 10 Amps @ 240 VACInput Voltage 90 – 264VACAuto-ranging YesLine Frequency 47 – 63HzMaximum Inrush Current 55 Amps per supply for 10ms or lessHot-Swap Capability YesOutput Power 570 Watts 870 WattsMaximum Heat Dissipation 1944.9 BTU per hour 2968.6 BTU per hourEfficiency (20% - 100%Load)86.9 – 90.5% @ 115 VAC88 – 92% @ 230 VAC85 – 88% @ 115 VAC87 – 90% @ 230 VAC1 Does not include the power supply handle or ejection tab5.7 Maximum Input AmpsMaximum input current (high-output power supply): 12A @ 90 VAC 6A @ 180 VAC