2. Remove the system cover.3. Remove the cooling shroud (see "Removing the Cooling Shroud").4. Locate the memory module sockets in which you will remove memory modules.Figure 6-9 shows the order of the memory module sockets.5. Press down and outward on the ejectors on each end of the socket until the memory module pops out of the socket (see Figure 6-11).Figure 6-11. Removing a Memory ModuleMicroprocessor UpgradesTo take advantage of future options in speed and functionality, you can add a second processor or replace either the primary or secondary processor.Each processor and its associated L2 cache memory are contained in a PGA package that is installed in a ZIF socket on the system board. The following subsectiondescribes how to install or replace the microprocessor in either the primary or secondary processor socket.Adding or Replacing a MicroprocessorIn addition to the ZIF socket for the primary microprocessor on the system board, there is a second ZIF socket to accommodate a secondary microprocessor. Thesecondary micro-processor must have the same operating frequency as the primary micro-processor. For example, if the system has a 933-MHz primarymicroprocessor, your secondary microprocessor must also be a 933-MHz microprocessor.In a single microprocessor system, the microprocessor must be installed in the primary ZIF socket.The following items are included in the microprocessor upgrade kit:l A microprocessor chipl A heat sinkl A securing clipl A VRM, if adding a second processor1. Open the front bezel (see "Removing the Front Bezel" in "Troubleshooting Your System").2. Remove the system cover.3. Remove the cooling shroud (see "Removing the Cooling Shroud").4. Press down on the heat-sink securing clip to release the clip from the retaining tab on the ZIF socket (see Figure 6-12).5. Remove the securing clip.NOTICE: The second processor must be of the same type and speed as the first processor.NOTE: Dell recommends that only a technically knowledgeable person perform this procedure.CAUTION: See "Protecting Against Electrostatic Discharge" in the safety instructions in your System Information document.CAUTION: Never remove the heat sink from a microprocessor unless you intend to remove the microprocessor. The heat sink is necessary to