Error Code Message InformationAMP0302 Message The system board <name> current is greater than the upper warningthreshold.Details System board <name> current is outside of the optimum range.Action 1. Review system power policy.2. Check system logs for power related failures.3. Review system configuration changes.4. If the issue persists, see Getting Help.AMP0303 Message The system board <name> current is greater than the upper criticalthreshold.LCD Message System board <name> current is outside of range.Details System board <name> current is outside of the optimum range.Action 1. Review system power policy.2. Check system logs for power related failures.3. Review system configuration changes.4. If the issue persists, see Getting Help.ASR0000 Message The watchdog timer expired.Details The operating system or an application failed to communicate withinthe time-out period.Action Check the operating system, application, hardware, and system eventlog for exception events.ASR0001 Message The watchdog timer reset the system.Details The operating system or an application failed to communicate withinthe time-out period. The system was reset.Action Check the operating system, application, hardware, and system eventlog for exception events.ASR0002 Message The watchdog timer powered off the system.Details The operating system or an application failed to communicate withinthe time-out period. The system was shut down.Action Check the operating system, application, hardware, and system eventlog for exception events.126