Configure the Top Storage ControllerConfigure the top storage controller (storage controller 1) with the information provided in the pre-installation documents.PrerequisitesCreate a serial connection from a computer to the storage controller, as described in Establish a SerialConnection to the Top Storage Controller.About this taskConfigure the top storage controller with the lower HSN, IP addresses for the Ethernet managementinterface (eth0) and baseboard management controller (BMC), one or more DNS servers, and the domainname.Figure 84. Storage Controllers1. Top storage controller (storage controller 1) 2. Bottom storage controller (storage controller2)Steps1. In the terminal emulator, press Enter several times to initiate the connection to the storagecontroller. The terminal emulator displays the prompt sn0> to indicate that thestorage controller is in Safe Mode.2. Run the following command to enter the shellacess developer mode.shellaccess developer3. Run the following command to display the prejoin configuration information that must be specified.platform prejoin showExample: sn0> platform prejoin show****************************************************************Prejoin configuration:System (License) Serial Number: 0Item Value------------ --------------------------------Canister 0HSN 0eth0 IPv4 0.0.0.0/32eth0 IPv6 ::/128eth1 IPv4 169.254.1.101/30eth1 IPv6 ::/128gateway IPv4 0.0.0.0gateway IPv6 ::DomainDNS Server 0 0.0.0.0Set up Storage Center Software 101