Ethernet & Sequencer Programming SM15K5 / 44 DELTA ELEKTRONIKA B.V. rev. Aug. 20192 Installation2.1 InfrastructureTo control or program the power supply, the Ethernet interface should be connected to a TCP/IP network,using the RJ45 connector at the rear (connector LAN). A standard RJ45 patch- or cross-link cable can beused to connect the Ethernet interface to a network switch, or directly to a PC. The Ethernet interface of theSM15K is Auto-MDIX. This means that for example a patch cable can be used for a direct connection,instead of using a cross-link cable. The "LNK"- LED of the Ethernet interface will be on when theconnection is okay.Either Cross-Link or standard Ethernet cable can be used.The command "PING " of Windows can be used (via menu Start - RUN - CMD) to check theconnection. For example: PING 10.1.0.101.2.2 SettingsEach network has its own range of IP addresses. To be able to control the SM15K via a particular network,the IP address of the Ethernet interface must be within the address range of that network.Recommended address ranges are:Class A: 10.0.0.0 to 10.255.255.255 (mask: 255.0.0.0)Class B: 172.16.0.0 to 172.31.255.255 (mask: 255.240.0.0)Class C: 192.168.0.0 to 192.168.255.255 (mask: 255.255.0.0)With exception of all addresses ending with '0' or '255'.Warning: Addresses above 223.255.255.255 are not supported on several operating systems.The TCP/IP settings of the SM15K can be set using the front panel, the internal web page1, or using the DEConfigurator program2.1) The PC has to be set to the IP range of the power supply to view the internal web page.2) The DE Configurator program is available for download on http://www.DeltaPowerSupplies.com/.Please see the Downloads section under, Products, SM15K.