Ethernet & Sequencer Programming SM15K9 / 44 DELTA ELEKTRONIKA B.V. rev. Aug. 20195.2 Source Subsystem5.2.1 IntroductionThe parameters (output voltage / output current / output power) have a working range from 0 to themaximum output voltage / current / power of the power supply. The response strings contain integers (max.values) or floating point values with 4 digits of precision (set values).5.2.2 Maximum Output VoltageTo read the maximum output voltage, send the query:Syntax : SOURce:VOLtage:MAXimum?For example the answer is: 5005.2.3 Maximum Output CurrentTo read the maximum output current, send the query:Syntax : SOURce:CURrent:MAXimum?5.2.4 Maximum Output Current NegativeTo read the maximum negative output current, send the query:Syntax : SOURce:CURrent:NEGative:MAXimum?5.2.5 Maximum Output PowerTo read the maximum output power, send the query:Syntax : SOURce:POWer:MAXimum?5.2.6 Maximum Output Power NegativeTo read the maximum negative output power, send the query:Syntax : SOURce:POWer:NEGative:MAXimum?5.2.7 Set Output VoltageTo set the output voltage of the power supply:Syntax : SOURce:VOLtageTo read the last settings, send the query:Syntax : SOURce:VOLtage?For example the answer is: 14.00005.2.8 Set Output CurrentTo set the output current of the power supply:Syntax : SOURce:CURrentTo read the last settings, send the query:Syntax : SOURce:CURrent?5.2.9 Set Output Current NegativeTo set the output current nagative of the power supply:Syntax : SOURce:CURrent:NEGative