1. Read complete instructions and familiarize yourself with the illustrations before beginning. Plumber installation is recommended.2. WARNING! SHUT OFF WATER SUPPLIES BEFORE DISASSEMBLING TUB SHOWER VALVE.3. Remove handle.4. Pull sleeve (1) off. Then, if necessary, slide the O-ring (2) toward you just below the back of the bonnet (3) on the body. Do not pull theO-ring over the bonnet. Note: When the sleeve (1) is reinstalled, it will slide on this O-ring.5. WARNING: BE SURE WATER SUPPLIES ARE SHUT OFF!6. Unscrew the brass bonnet (3) counterclockwise.7. Determine which series cartridge is currently installed in order to know which replacement cartridge to use. If the cap (4) is white,a 1300/1400 series cartridge (RP19804) is currently installed. If the cap (4) is grey, a 13/14 MultiChoice™ cartridge (RP46074) iscurrently installed. Note: Cartridges are not interchangeable.8. Remove the cartridge from the body. If a 13/14 MultiChoice™ cartridge (RP46074) is installed, place a flat head screwdriver in the notch (5)of the cap and turn to raise out of the body.Note: If a 1300/1400 cartridge (RP19804) is installed, do not pry the cartridge out of the body with a screwdriver. Reinstall thehandle on the brass stem and rotate counterclockwise while lifting the cartridge out of the two notches (6) on the sides of the body.9. CAUTION! Do not twist the cap (4) and the lower housing (7) of the new cartridge to take it apart. If the parts are separated for anyreason, be sure to lock each together by twisting the parts together until the cap and housing snap together. WARNING! Never take thelower housing apart.1. 1300/1400 Cartridge Installation:Install the cartridge with the wording “Hot Side” located on the hot water inlet side. Press into valve body, making sure the keys (8) are fullyengaged with the slots of the body (6). Note: For back-to-back or reverse installations (hot on right, cold on left) install cartridge with thewording “Hot Side” on the hot water inlet side. If using a 13/14 MultiChoice™ cartridge, see step 1A below. If not, continue to step 2.13/14 Multi-Choice Cartridge Installation:Install the cartridge with the wording “Hot Side” located on the hot water inlet side. Press into valve body, making sure the keys (8) are fullyengaged with the slots of the body (6). Note: For back-to-back or reverse installations (hot on right, cold on left) install cartridge with thewording “Hot Side” on the hot water inlet side.2. Reassemble the brass bonnet (3).3. Slide the sleeve (1) over the O-ring.4. Remove and throw away the black retention plug (not illustrated), on 1300/1400 cartridge only, from the brass stem.5. See the reverse side for rotational limit stop adjustment.6. Reinstall the handle, then proceed to step 7.7. FLUSH YOUR SYSTEM. Turn on water supplies. Check for leaks and let supply lines flush for one minute without moving handle. If youhave a showerhead remove and divert water to it and flush for 30 seconds. This will remove any debris from the supply lines that candamage internal parts of the faucet and create leaks. BE SAFE! After you have finished the repair, turn on tub/shower valve to make sureCOLD WATER FLOWS FIRST.RP480251300/1400 & 13/14 CartridgesInstallation Instructions132457613247648027 48027 48027 48027 48027 4802748027 48027 48027 48027 48027 48027110/13/06 Rev. B13/14 MultiChoice™ CartridgeRP460741300/1400 CartridgeRP19804881A.