6104163PROPANE CONSTRUCTION HEATER30,000 BTU/HrSTORAGE1. Store propane tank(s) in safe manner.See Chapter 5 of Standard for Storageand Handling of Liquefied PetroleumGases, ANSI/NFPA 58. Follow all lo-cal codes. Always store propane tanksoutdoors.2. Place plastic cover caps over brassfittings on inlet connector and hose/regulator assembly.3. Store in dry, clean, and safe place. Donot store hose/regulator assembly in-side heater combustion chamber.4. When taking heater out of storage, al-ways check inside of heater. Insects andsmall animals may place foreign ob-jects in heater. Remove motor and otherinternal parts if needed to remove for-eign objects (see Service Procedures,page 8).MAINTENANCECAUTION: Disconnect heaterfrom propane supply tank(s).WARNINGS• Never service heater while it isplugged in, connected to pro-pane supply, operating, or hot.Severe burns and electricalshock can occur.• Keep heater clear and free fromcombustible materials, gaso-line, and other flammable va-pors and liquids.• Do not block the flow of com-bustion or ventilation air.1. Keep heater clean. Clean heater annu-ally or as needed to remove dust anddebris. If heater is dirty or dusty, cleanheater with a damp cloth. Use house-hold cleaners on difficult spots.2. Inspect heater before each use. Checkconnections for leaks. Apply mixtureof liquid soap and water to connections.Bubbles forming show a leak. Correctall leaks at once.3. Inspect hose/regulator assembly be-fore each use. If hose is highly wornor cut, replace with hose specified bymanufacturer.SPECIFICATIONSOutput Rating (BTU/Hr) 30,000Fuel Propane Vapor OnlyFuel ConsumptionGallons/Hour .33Pounds/Hour 1.4Supply Pressure To RegulatorMinimum (for purposes 20 psiof input adjustment)Maximum Tank Pressure or 200 psiRegulator Outlet Pressure 10 PSIManifold Pressure 10.1 PSIHot Air Output(CFM Approx) 175Motor 3045 RPMElectric Input 120 volt/60 hertzAmperage .6Ignition Manual, PiezoWeight (Pounds)Heater 9Shipping 9.5Size - L x W x H (Inches)Heater 18.5 x 7.7 x 12.8Temperature Range for Heater Operation -20° F to 85° F** When running heater in temperatures above 85° F, high internal temperatures may causethermal limit device to shut down heater.4. Have heater inspected yearly by a quali-fied service agency.5. Keep inside of heater free from com-bustible and foreign objects. Removemotor and other internal parts if neededto clean inside of heater (see ServiceProcedures, page 8).6. Clean fan blades each season or asneeded (see Fan, page 9).