20102991OPERATINGHEATERManually-Controlled Models1. STOP! Read the safety information above.2. Make sure manual shutoff valve is fully open.3. Press in and turn control knob clockwise Clockwise to the OFF position.Figure 21 - Control Knob and Ignitor Button Location4. Wait five (5) minutes to clear out any gas. Then smell for gas, including near thefloor. If you smell gas, STOP! Follow “B” in the safety information above. If youdon’t smell gas, go to the next step.PILOTOFFLOHIControl KnobIgnitor ButtonFOR YOUR SAFETY READ BEFORE LIGHTINGWARNING ICON G 001WARNINGIf you do not follow these instructions exactly, a fire or explosion mayresult causing property damage, personal injury or loss of life.A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,follow these instructions exactly.B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smellnext to the floor because some gas is heavier than air and will settle on the floor.WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electric switch; do not use any phone in your building.• Immediately call your gas supplier from a neighbor’s phone. Follow the gassupplier’s instructions.• If you cannot reach your gas supplier, call the fire department.C. Use only your hand to push in or turn the gas control knob. Never use tools. If theknob will not push in or turn by hand, don’t try to repair it, call a qualified servicetechnician or gas supplier. Force or attempted repair may result in a fire orexplosion.D. Do not use this appliance if any part has been under water. Immediately call aqualified service technician to inspect the appliance and to replace any part of thecontrol system and any gas control which has been under water.LIGHTING INSTRUCTIONSWARNING ICON G 001WARNING• If fireplace has glass doors, never operate this heater with glass doorsclosed. If you operate heater with doors closed, heat buildup insidefireplace will cause glass to burst. Also if fireplace opening has vents atthe bottom, you must open the vents before operating heater.• You must operate this heater with a fireplace screen in place. Make surefireplace screen is closed before running heater.NOTICEDuring initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper orwindow to vent smell. This will only last a few hours.Note: Homeowners generally prefer to operate their heater with the chimney damperclosed. This will put all the heat into the room. However there may be times you willdesire the full flames of the Hi heat setting but will find the heat output excessive. Youcan open the chimney damper (if you have one) fully or partially to release some ofthe heat. WARNING: Damper handle will be hot if heater has been running.