www.desatech.com 119526-01A4SAFETy INFORMATIONContinued6. Do not add extra logs or ornaments such aspine cones, vermiculite or rock wool. Usingthese added items can cause sooting. Do notadd lava rock around base. Rock and debriscould fall into the control area of fireplace.7. To prevent the creation of soot, follow the instruc-tions in Cleaning and Maintenance, page 24.8. Before using furniture polish, wax, carpetcleaner or similar products, turn heater off. Ifheated, the vapors from these products maycreate a white powder residue within burnerbox or on adjacent walls or furniture.9. This fireplace needs fresh air ventilation to runproperly. This fireplace has an Oxygen Deple-tion Sensing (ODS) safety shutoff system. TheODS shuts down the fireplace if enough freshair is not available. See Air for Combustionand Ventilation, page 5. If fireplace keepsshutting off, see Troubleshooting, page 25.10. Do not run fireplace• where flammable liquids or vapors are usedor stored• under dusty conditions11. Do not use this fireplace to cook food or burnpaper or other objects.12. Do not use fireplace if any part has been exposedto or under water. Immediately call a qualifiedservice technician to inspect the fireplace and toreplace any part of the control system and anygas control which has been under water.13. Do not operate fireplace if any log is broken.Do not operate fireplace if a log is chipped(dime-sized or larger).14. Turn fireplace off and let cool before servic-ing. Only a qualified service person shouldservice and repair fireplace.15. Operating fireplace above elevations of 4,500feet could cause pilot outage.16. To prevent performance problems in propane/LPunits, do not use propane/LP fuel tanks of lessthan 100 lbs. capacity (propane/LP units only).17. Provide adequate clearances around airopenings.Figure 2 - Fireplace (LMFP33PR Shown)Figure 1 - Log Base AssemblyOFFPILOTON4-Piece Log Set(A Models shown)RemoteReceiverPiezoIgnitorRemote ControlControlKnobTop LouverAssemblyFireboxHoodBottom Louver AssemblyScreenAssemblyTop Outer CasingFireboxSupportBlowerAssembly(Optional)LOCAL CODESInstall and use fireplace with care. Follow all localcodes. In the absence of local codes, use the lat-est edition of The National Fuel Gas Code ANSIZ223.1/NFPA 54*.*Available from:American National Standards Institute, Inc.1430 BroadwayNew York, NY 10018National Fire Protection Association, Inc.Batterymarch ParkQuincy, MA 02269Note: Where listed vented decorative logs arerequired, thermostat operation is not permitted.PRODUCTIDENTIFICATION