111252-01EFor more information, visit www.desatech.comFor more information, visit www.desatech.com2525OPERATING FIREPLACELIGHTINGINSTRUCTIONS1. STOP! Read the safety information above.2. Open lower louver panel.3. Turn off all electric power to the fireplace.4. Push in gas control knob slightly and turn clockwiseto “OFF”.5. Wait five (5) minutes to clear out any gas. Then smell forgas, including near the floor. If you smell gas, STOP! Fol-low “B” in the safety information above. If you don't smellgas, go to the next step.6. The pilot is located by the main burner and should not re-quire accessing for lighting.7. Turn gas control knob counterclockwise to “PILOT”.8. Push in gas control knob all the way and hold. Immedi-ately light the pilot by repeatedly depressing the piezo sparkignitor until a flame appears. Continue to hold for aboutone (1) minute after the pilot is lit. Release gas control knoband it will pop back. Pilot should remain lit. If it goes out,repeat steps 5 through 8.• If gas control knob does not pop up when released, stop andimmediately call your service technician or gas supplier.• If the pilot will not stay lit after several tries, turn thegas control knob to “OFF” and call your service techni-cian or gas supplier.OPERATING FIREPLACEFor Your Safety Read Before LightingLighting InstructionsTo Turn Off Gas To ApplianceManual Lighting ProcedureTO TURN OFF GASTO APPLIANCE1. Open lower louver panel.2. Set selector switch in the OFF position to prevent drainingbattery.3. Turn off all electrical power to the appliance if service is tobe performed.4. Push in gas control knob slightly and turn clockwiseto “OFF”.5. Close lower louver panel.Shutting Off Burners Only (pilot stays lit)You may shut off the burners and keep the pilot lit by doing oneof the following:1. Turn gas control knob clockwise to the PILOT po-sition.2. Set selector switch in the OFF position.MANUAL LIGHTINGPROCEDURE1. Remove glass door (see Removing/Replacing Glass Door,page 22).2. Follow steps 1 through 8 under Lighting Instructions.3. Depress gas control knob and light pilot with match.4. Keep gas control knob pressed in for 30 seconds after light-ing pilot. After 30 seconds, release gas control knob. Fol-low steps 10 through 14 under Lighting Instructions.5. Replace glass door (see Removing/Replacing Glass Door,page 22).OFFPILOTON LOIHFigure 52 - Control ValvePiezoIgnitorGas ControlKnobVariable Control KnobWARNING: If you do not follow these instructionsexactly, a fire or explosion may result causing prop-erty damage, personal injury or loss of life.A. This appliance has a pilot which must be lighted by hand.When lighting the pilot, follow these instructions exactly.B. BEFORE LIGHTING smell all around the appliance areafor gas. Be sure to smell next to the floor because some gasis heavier than air and will settle on the floor.WHAT TO DO IF YOU SMELL GAS• Do not try to light any appliance.• Do not touch any electric switch; do not use any phonein your building.• Immediately call your gas supplier from a neighbor'sphone. Follow the gas supplier's instructions.C. Use only your hand to push in or turn the gas control knob.Never use tools. If the knob will not push in or turn by hand,don't try to repair it, call a qualified service technician. Forceor attempted repair may result in a fire or explosion.D. Do not use this appliance if any part has been under water.Immediately call a qualified service technician to inspectthe appliance and to replace any part of the control systemand any gas control which has been under water.FOR YOUR SAFETY READBEFORE LIGHTING9. Turn on all electric power to the fireplace.10. Turn gas control knob counterclockwise to “ON”.11. This valve is equipped with a HI/LO feature. Set fireplaceinput as desired.12. Close lower louver panel.