108861For more information, visit www.desatech.comFor more information, visit www.desatech.com10Horizontal HighWind SquareTerminationWallFirestop45° ElbowFigure 14 - Horizontal Termination Configuration for Square orRound Terminations45° ElbowWallFirestopHorizontalRoundTerminationExterior Portion of WallFirestop (RoundTermination Only)GROUND FLOOR INSTALLATIONRecommended Applications:• Installation using cabinet surrounds• Through the wall using round or square termination(up to 12" horizontal pipe)• NOT FOR CORNER INSTALLATIONVENTING INSTALLATIONINSTRUCTIONSContinuedVENTING INSTALLATION INSTRUCTIONSInstallation Planning (Cont.)AdjustablePipe 12" Max.Horizontal Termination ConfigurationsFigures 14 through 18 show different configurations and alternativesfor venting with horizontal termination. Each figure includes a chartwith critical minimum and maximum dimensions which MUST bemet.IMPORTANT: Remember that a horizontal run of venting musthave a 1/4" rise for every 12" of run toward the termination.Figure 13 - Typical Horizontal Termination Cap Mounting withAdditional Siding Standoff InstalledSiding StandoffScrewsHigh WindTerminationApply Mastic toOutside Edge ofStandoffExterior Wallwith Vinyl Siding10 3 /4 " x 10 3/4 "FramedOpeningMaintain 1"Minimum AirSpace AroundOuter Pipe WhenPenetrating a WallMinimum PipeOverlap 11 /4 "WallFirestopDirect VentPipeWARNING: Never run vent downward as this maycause excessive temperatures which could cause afire. Operation of improperly installed and main-tained venting system could result in serious injury,property damage or loss of life.9. Slide wall firestop against interior wall surface and attach withscrews provided. See Figure 13 for horizontal termination details.10. Place fireplace into position and shim with noncombustible ma-terial if needed. Nail or screw side flanges to framing to secureunit in place.IMPORTANT: Make sure fireplace is level beforesecuring. If fireplace is not level it will not work properly.Round Termination(Kit 01491 for V36, V42 SeriesKit SDHTRK-58 CHDV Series)Square TerminationVertical (V) Horizontal (H)V36 Series 35" min. 17" max.V42 Series 39" min. 17" max.CHDV Series 39" min. 17" max.