www.desatech.com 111906-01F6FixedClosed Openable FixedClosedOpenableVVVVV VVVXXV XGGJFBBKNHIANELDBMACBVV AGGBTERMINATION CAP AIR SUPPLY INLET GAS METER RESTRICTED AREA(TERMINATION PROHIBITED)A = clearance above grade, veranda, porch, deck, or balcony[*12" (30.5 cm) minimum]B = clearance to window or door that may be opened[12" (30.5 cm) minimum]C = clearance to permanently closed window [minimum 12" (30.5 cm)recommended to prevent condensation on window]D = vertical clearance to ventilated soffit located above the terminalwithin a horizontal distance of 24" (61cm) from thecenter-line of the terminal [18" (45.7 cm) minimum]E = clearance to unventilated soffit [12" (30.5 cm) minimum]F = clearance to outside corner (see below)G = clearance to inside corner (see below)H = *not to be installed above a meter/regulator assembly within36" (91.4 cm) horizontally from the center-line of the regulatorI = clearance to service regulator vent outlet [*72" (182.9 cm)minimum]J = clearance to non-mechanical air supply inlet to building or thecombustion air inlet to any other fireplace [*12" (30.5 cm)minimum]K = clearance to a mechanical air supply inlet [*72" (182.9 cm)minimum]L = † clearance above paved side-walk or a paved driveway located onpublic property [*84" (213.3 cm) minimum]M = clearance under veranda, porch, deck [*12" (30.5 cm) minimum ‡]N = clearance above a roof shall extend a minimum of 24" (61 cm)above the highest point when it passes through the roof surface andany other obstruction within a horizontal distance of 18" (45.7 cm)† vent shall not terminate directly above a side-walk or paved driveway which is located between twosingle family dwellings and serves both dwellings*‡ only permitted if veranda, porch, deck or balconey is fully open on a minimum of 2 sides beneath the floor** as specified in CAN/CSA B149 (.1 or .2) Installation Codes (1991) for Canada and U.S.A.Note: Local codes or regulations may require different clearancesA = 6" (15.2 cm)Inside CornerVBEVB = 6" (15.2 cm)C = Maximum depth of 48" (121.9 cm) forrecessed locationD = Minimum width for back wall ofrecessed location -Combustible - 38" (96.5 cm)Noncombustible - 24" (61cm)E = Clearance from corner inrecessed location-Combustible - 6" (15.2 cm)Noncombustible - 2" (5.1 cm)Outside Corner Recessed LocationGHG = 12" (30.5 cm) minimum clearanceBalcony with No Side WallVJCombustible &NoncombustibleH = 24" (61 cm)J = 20" (50.8 cm)Balcony with Perpendicular Side WallCDCTermination Clearances for Buildings with Combustible and Noncombustible ExteriorsFigure 7 - Minimum Clearances for Termination CapLOcATION OF TERMINATION cAP