110720-01B16For more information, visit www.desatech.comFor more information, visit www.desatech.comTROUBLESHOOTINGTROUBLESHOOTING WARNING: Turn off heaterand let cool before servicing. Onlya qualified service person shouldservice and repair heater.POSSIBLE CAUSE1. Ignitor electrode positioned wrong2. Ignitor electrode broken3. Ignitor electrode not connected to igni-tor cable4. Ignitor cable pinched or wet5. Piezo ignitor nut is loose6. Broken ignitor cable7. Bad piezo ignitor1. Gas supply turned off or equipmentshutoff valve closed2. Control knob not in PILOT position3. Control knob not pressed in while inPILOT position4. Air in gas lines when installed5. Depleted gas supply (propane/LP only)6. ODS/pilot is clogged7. Gas regulator setting is not correct1. Control knob not fully pressed in2. Control knob not pressed in long enough3. Equipment shutoff valve not fully open4. Thermocouple connection loose at con-trol valve5. Pilot flame not touching thermocouple,which allows thermocouple to cool,causing pilot flame to go out. This prob-lem could be caused by one or both ofthe following:A) Low gas pressureB) Dirty or partially clogged ODS/pilot6. Thermocouple damaged7. Control valve damagedOBSERVED PROBLEMWhen ignitor button is pressed, there is nospark at ODS/pilotWhen ignitor button is pressed, there isspark at ODS/pilot but no ignitionODS/pilot lights but flame goes out whencontrol knob is releasedREMEDY1. Replace pilot assembly2. Replace pilot assembly3. Reconnect ignitor cable4. Free ignitor cable if pinched by anymetal or tubing. Keep ignitor cable dry5. Tighten nut holding piezo ignitor toheater cabinet. Nut is located insideheater cabinet at top6. Replace ignitor cable7. Replace piezo ignitor1. Turn on gas supply or open equipmentshutoff valve2. Turn control knob to PILOT position3. Press in control knob while in PILOTposition4. Continue holding down control knob.Repeat igniting operation until air is re-moved5. Contact local propane/LP gas company6. Clean ODS/pilot (see Cleaning andMaintenance, page 15) or replace ODS/pilot assembly7. Replace gas regulator1. Press in control knob fully2. After ODS/pilot lights, keep controlknob pressed in 30 seconds3. Fully open equipment shutoff valve4. Hand tighten until snug, then tighten 1/4turn more5. A) Contact local natural or propane/LPgas companyB) Clean ODS/pilot (see Cleaning andMaintenance, page 15) or replace ODS/pilot assembly6. Replace pilot assembly7. Replace control valveCAUTION: Never use a wire,needle, or similar object to cleanODS/pilot. This can damage ODS/pilot unit.Note: For additional help, visit DESAInternational’s technical service web siteat www.desatech.com.Note: All troubleshooting items are listed inorder of operation.