15104323OWNER’S MANUALONPOSITIONOFFPOSITIONPressure Testing Gas SupplyPiping SystemTest Pressures In Excess Of 1/2 PSIG1. Disconnect fireplace and its individualmanual shutoff valve from gas supplypiping system. Pressures in excess of1/2 psig will damage fireplace regulator.2. Cap off open end of gas pipe wheremanual shutoff valve was connected.3. Pressurize supply piping system by ei-ther using compressed air or openingpropane/LP supply tank valve.4. Check all joints of gas supply pipingsystem. Apply mixture of liquid soapand water to gas joints. Bubbles form-ing show a leak.5. Correct all leaks at once.6. Reconnect heater manual shutoff valveto gas supply. Check reconnected fit-tings for leaks.OpenClosedManualShutoffValveFigure 27 - Checking Gas Joints Shown with Optional MantelCHECKING GASCONNECTIONSFigure 26 - Manual Shutoff ValveManualShutoffValvePropane/LPSupply TankWARNING: Test all gas pip-ing and connections for leaksafter installing or servicing. Cor-rect all leaks at once.WARNING: Never use an openflame to check for a leak. Apply amixture of liquid soap and waterto all joints. Bubbles formingshow a leak. Correct all leaks atonce.Test Pressures Equal To or Less Than1/2 PSIG1. Close manual shutoff valve (see Fig-ure 26).2. Pressurize supply piping system by ei-ther using compressed air or openingpropane/LP supply tank valve.3. Check all joints from propane/LP sup-ply tank to manual shutoff valve (seeFigure 27). Apply mixture of liquidsoap and water to gas joints. Bubblesforming show a leak.4. Correct all leaks at once.Pressure Testing Fireplace GasConnections1. Open manual shutoff valve (seeFigure 26).2. Open propane/LP supply tank valve.3. Make sure control knob of fireplace isin the OFF position.4. Check all joints from manual shutoffvalve to thermostat gas valve (see Fig-ure 26). Apply mixture of liquid soapand water to gas joints. Bubbles form-ing show a leak.5. Correct all leaks at once.6. Light fireplace (see Operating Fire-place, pages 18 through 20). Check allother internal joints for leaks.7. Turn off fireplace (see To Turn Off Gasto Appliance, page 19).8. Replace front panel.INSTALLATIONContinuedCAUTION: Make sure externalregulator has been installed be-tween propane/LP supply and fire-place. See guidelines underCon-necting to Gas Supply, page 13.Continued