UPS Operating InstructionsEaton 9E UPS (40–60 kVA, 208/220V) Installation and Operation Manual P-164000058—Rev 4 www.eaton.com/powerquality 6-76.2.6 Display Menu OperationTable 6-3 describes the menu functions and how to use them.Table 6-3. Display Menu OperationFunction Subfunction OperationMeters – UPS The Meter screens show the UPS meter readings for the unit. The default voltage displayed on thesescreens is phase-to-neutral. These can be changed to display the voltage phase-to-phase(A-B, B-C, C-A). Use the LEFT or RIGHT arrow pushbuttons to select the METER symbol on the mainmenu bar, to display the Meter screens. To scroll through the meter screens, press the UP or DOWNarrow pushbutton. The current UPS readings are displayed in the information area of the screen.Output – UPS The Output screen shows output voltage (phasetoneutral), output current (each phase), and frequencybeing supplied by the UPS, as well as the kVA, kW, and power factor measurements.Input – UPS The Input screen shows input voltage (phasetoneutral), input current (each phase), and frequency ofthe incoming utility source, as well as the kVA, kW, and power factor measurements.Bypass The Bypass screen shows the bypass input voltage (phasetoneutral), input current (each phase), andfrequency of the incoming utility source, as well as the kVA, kW, and power factor measurements.Battery – UPS The Battery screen displays the battery voltage (Vdc) and the battery current (Idc).Events Use the LEFT or RIGHT arrow pushbuttons to select the EVENTS symbol on the main menu bar todisplay the Events screens. A listing of all system events that are currently active is displayed. Themost recent event is listed first. As events clear, they are removed from the Events listing. To scrollthrough the events, press the UP or DOWN arrow pushbutton.History Use the LEFT or RIGHT arrow pushbuttons to select the HISTORY symbol on the main menu bar todisplay the History screen. The history Log lists up to 512 events in chronological order, with the mostrecent event listed last (once 512 is reached, the earliest event is overwritten). The end of the log (themost recent events) is displayed first; scroll upward to view older event listings. To scroll through theevents, press the UP or DOWN arrow pushbutton.Setup – User Function Selection This screen can be used to display user information and show the firmware versions installed. Use theLEFT or RIGHT arrow pushbuttons to select the SETUP symbol on the main menu bar to display theSetup screen. Use the UP or DOWN arrow pushbutton to highlight the function desired, then pressthe RETURN pushbutton to display the function screen. See Figure 6-6 for a typical screen display.User Info The User Info screen provides the model, CTO and serial numbers of the UPS, the Output voltage,frequency, and kVA rating, the input voltage rating, and the battery run time rating. Use the LEFT orRIGHT arrow pushbuttons to select USER on the Setup menu bar. Use the UP or DOWN arrowpushbutton. to select Info, then press the RETURN pushbutton to display the function screen. Toreturn to the System Setup screen, press the ESC pushbutton.About The About screen provides the firmware version numbers installed on the UPS. Use the LEFT orRIGHT arrow pushbuttons to select USER on the Setup menu bar. Use the UP or DOWN arrowpushbutton. to select About. To return to the System Setup screen, press the ESC pushbutton.Setup – Config(System Level 1 Setup)Password To enter a password if required, use the LEFT or RIGHT arrow pushbutton to select the passwordcharacter position. Use the UP or DOWN arrow pushbutton to change the password character. Oncethe password is entered, select DONE and then press the RETURN pushbutton. The System SetupLevel 1 menu screen is displayed. The default System Setup Level 1 password is 0101.Function Selection This screen can be used to set the date and time, change the display language, enter a unit name,change the meter style, perform lamp test, clear the history log, and enter a password to accessLevel 1 functions. Use the LEFT or RIGHT arrow pushbuttons to select the SETUP symbol on the mainmenu bar to display the Setup screen. Use the LEFT or RIGHT arrow pushbutton to select CONFIGon the Setup menu bar. Enter a password if required.Clock The Clock Setup screen allows the selection of either month/day/year or day/month/year formats anddaylight savings time for display on the screen and for logging events in the Event and History Logs.Use the UP or DOWN arrow pushbutton to select CLOCK to display the Clock screen. Use the UP orDOWN arrow pushbutton to highlight the desired format, then press the RETURN pushbutton todisplay the Set Date and Time screen. To return to the System Setup screen, press the ESCpushbutton.