EATON WSB11206 WCSB Tensioner / Brake with ORB Coolant Ports Installation, Operation and Maintenance Manual E-CLCL-II009-E August 2015 31WCSB tensioner / brake with ORB coolant ports4.9.26 Remove the screws (20) one at a time, applyLoctite #262 to the screw threads, and reinstall thescrew, tightening to the value shown in Table 2.Repeat for the remaining screws.WarningLoctite ® may cure prior to properly tightening thescrew if not tightened to the proper torque valueimmediately after installation.CautionLoctite ® #262 must be shaken prior to application.CautionLoctite ® #262 may irritate sensitive skin. Refer to theproduct label for proper safety precautions.CautionThe locknuts (18) and sleeve nuts (106) must betightened gradually to prevent damage to thebrake components.4.9.27 After assembly, check gaps "W" and "Z-1" to ensurethat the brake will have adequate running clearanceswhen released. Refer to Figure 7 and Table 9.Additional machining of friction discs or wear platesmay be required to achieve proper running clearancesif gaps Wnew and Znew are not found to be withinthe ranges shown on Table 8. Correct as required.4.9.28 Prior to installation, air test the cylinder seals forleakage per Section 4.6.9.4.9.29 Install the WCSB tensioner per Section 2.0.5.0 ORDERING INFORMATION /TECHNICAL ASSISTANCE5.1 Equipment Reference5.1.1 In any correspondence regarding Airflex equipment,refer to the information on the product nameplateand call or write:EatonHydraulics Group USAAirflex Products9919 Clinton Rd.Cleveland, Ohio44144Tel: (216) 281-2211Fax: (216) 281-3890www.eaton.com/hydraulicsLoctite, Locquic, and Superflex are registeredtrademarks of Henkle Corporation.Molykote ® is a registered trademark ofDow CorningPLASITE Epoxy #9052 is a registered trademark ofThe Carboline Company.MOLUB-ALLOY is a trademark ofCastrol Industrial Lubricants.