Eaton IQ 35M Series Quick Start Manual
Contents |
Quick Start Guide1 IQ 35M Meter Series IB02601008E September 2011 www.eaton.com ZL0073-0CIQ 35M Meter SeriesRoHSCompliantHAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH• Follow safe electrical work practices. See NFPA 70E in the USA, or applicable local codes.• This equipment must only be installed and serviced by qualified electrical personnel.• Read, understand and follow the instructions before installing this product.• Turn off all power supplying equipment before working on or inside the equipment.• Any covers that may be displaced during the installation must be reinstalledbefore powering the unit.• Use a properly rated voltage sensing device to confirm power is off.DO NOT DEPEND ON THIS PRODUCT FOR VOLTAGE INDICATIONFailure to follow these instructions will result in death or serious injury.DANGERNOTICE• This product is not intended for life or safety applications.• Do not install this product in hazardous or classified locations.• The installer is responsible for conformance to all applicable codes.• Mount this product inside a suitable fire and electrical enclosure.This symbol indicates an electricalshock hazard exists.Documentation must be consulted wherethis symbol is used on the product.FCC PART 15 INFORMATIONNOTE: This equipment has been tested by the manufacturer and foundto comply with the limits for a class B digital device, pursuant to part15 of the FCC Rules. These limits are designed to provide reasonableprotection against harmful interference when the equipment isoperated in a residential environment. This equipment generates, uses,and can radiate radio frequency energy and, if not installed and usedin accordance with the instruction manual, may cause harmfulinterference to radio communications. Operation of this equipment ina residential area may cause harmful interference in which case theuser will be required to correct the interference at his own expense.Modifications to this product without the express authorization of themanufacturer nullify this statement.For use in a Pollution Degree 2 or better environment only. A Pollution Degree 2environment must control conductive pollution and the possibility of condensationor high humidity. Consider the enclosure, the correct use of ventilation, thermalproperties of the equipment, and the relationship with the environment. Installationcategory: CAT II or CAT IIIProvide a disconnect device to disconnect the meter from the supply source. Placethis device in close proximity to the equipment and within easy reach of the opera-tor, and mark it as the disconnecting device. The disconnecting device shall meetthe relevant requirements of IEC 60947-1 and IEC 60947-3 and shall be suitablefor the application. In the US and Canada, disconnecting fuse holders can be used.Provide overcurrent protection and disconecting device for supply conductors withapproved current limiting devices suitable for protecting the wiring. If the equipmentis used in a manner not specified by the manufacturer, the protection provided bythe device may be impaired.SpecificationsMeasurement Accuracy:Real Power and Energy IEC 62053-22 Class 0.5S, ANSI C12.200.5%Input Voltage Characteristics:Measured AC Voltage Min. 90 VL-N (156 VL-L) for stated accuracyUL Maximums: 600 VL-L (347 VL-N)CE Maximums: 300 VL-N (520 VL-L)Impedance 2.5 MΩ (L-N)/5 MΩ (L-L)Frequency Range 45 to 65 HzInput Current Characteristics:Measurement Input Range 0 to 0.333 VAC or 0 to 1.0 VAC(+20% over-range)Impedance 10.6 kΩ (1/3 V mode) or 32.1 kΩ (1 V mode)Control Power:AC 5 VA max.; 90 V min.UL Maximums: 600 VL-L (347 VL-N)CE Maximums: 300 VL-N (520 VL-L)DC * 3 W max.; UL and CE: 125 to 300 VDCRide Through Time 100 msec at 120VACMechanical Characteristics:IP Degree of Protection (IEC 60529) IP40 front display; IP20 MeterTerminal Block Screw Torque 3.5 in-lb (0.4 N·m) nominal/4.4 in-lb (0.5 N·m) max.Terminal Block Wire Size 14 to 24 AWGRail T35 (35mm) DIN Rail per EN50022Environmental Conditions:Operating Temperature -30° to 70°CStorage Temperature -40° to 85°CHumidity Range <95% RH (non-condensing)Altitude of Operation 3 km max.Metering Category:North America CAT III; for distribution systemsup to 347 VL-N/600 VACL-LCE CAT III; for distribution systemsup to 300 VL-NDielectric Withstand Per UL 508, EN61010Conducted and Radiated Emissions FCC part 15 Class B, EN55011/EN61000Class B (residential and light industrial)Conducted and Radiated Immunity EN61000 Class A (heavy industrial)Safety:North America (cULus) UL508 (open type device)/CSA 22.2 No. 14-05Europe (CE) EN61010-1:2001* External DC current limiting is required. See Fuse RecommendationsCAUTIONRISK OF EQUIPMENT DAMAGE• This product is designed only for use with 1V or 0.33V currenttransducers (CTs).• DO NOT USE CURRENT OUTPUT (e.g. 5A) CTs ON THIS PRODUCT.• Failure to follow these instructions can result in overheating andpermanent equipment damage.Additional Resources:For a copy of the full installation guidefor this product, visit www.eaton.com |
Related manuals for Eaton IQ 35M Series
Eaton PXM4K Series Quick Start Manual
Eaton PXM4K Series Quick Start Manual
Eaton Xpert Meter 2000 Series Quick Start Manual
Eaton PXM 2250 Quick Start Manual
Eaton Moeller Series Manual
Eaton Power Xpert Meter 4000 Quick Start Manual
Eaton IQ 100 series User & Installation Manual
Eaton Power Xpert Meter PXM4000 Quick Start Manual
Eaton LifeSense Quick Setup Manual
Eaton xStorage Home Series Manual
manualsdatabase
Your AI-powered manual search engine