Eaton OSP10M Quick Start Manual
COMPLETING THE INSTALLATION:1. Install the sensor loosely using the mounting screws provided.2. Apply power temporarily and verify that the sensor works by pushing the ON/OFFbutton to verify the control load can operate properly (i.e. lights can turn on and off).In the case of controlling a Switchpack, skip STEP 3 altogether.3. If the lights do not work, then turn off the power and swap the connections on thesensor black and red wires. Apply power again and verify that the sensor works bypushing the ON/OFF button to verify the lights turn on and off.4. Turn power to the device OFF.5. Secure sensor into the wall box using two mounting screws provided. Turn thecircuit breaker ON.6. Allow the sensor to stabilize for 30 seconds. The sensor is now ready to detectmotion.7. Verify that Power is ON by pushing the ON/OFF button. Lights should turn ON.8. NOTE - The sensor time delay is factory preset (5 minutes).9. If you want to change the time delay proceed as follows:a. Remove the button from the sensor by pressing in thehooks on the button, and then lift up on the button asshown in Fig. 4.b. Set the time delay using the dial on the right side byusing a small Phillips screwdriver. Align the arrow onthe dial to desired time delay. See Fig. 5.c. To allow the installer to quickly confirm that the sensoris functioning properly the time delay can be set toTEST. This will set a time delay of 5 seconds, whichallows quick feedback that the sensor is work- ingproperly.10. Replace push button by sliding it upward into the slots inthe front housing and push down until the button hooksnaps into place.11. Push the ON/OFF button to verify that the lights turn ON/OFF, and that the button operates freely.12. Install the wallplate.Daylight Sensing Adjustment:• The Daylight sensing feature prevents lights fromturning ON when the room is adequately illuminat- edby natural light.• NOTE - The factory setting for this adjustment is fullyclockwise and permits motion detection to turn ONthe lights regardless of the ambient light level in theroom.• Remove the ON/OFF pushbutton to access the lightlevel adjustment. See Fig. 4.• This adjustment must be made when the light level inthe room is at the desired level for the lights to turnON.• From the clockwise position, turn the dial on the leftcounterclockwise using a small Phillips screwdriveruntil the LED starts to flash. See Fig. 5.• Step away from the sensor to allow the device tocalibrate to the normal light level in the room.Do not obstruct the natural light. The calibrationprocess starts when the LED and lights turn OFF, andwill take approximately 15 seconds. After completionthe lights will turn on.• Replace the ON/OFF pushbutton.TROUBLESHOOTING:If you have a problem with your Motion Sensor, first follow this guide. If the problem persists, call the customer service hotline at 1-866-853-4293 between 8:00 A.M. and 6:00 P.M. ESTweekdays.SYMPTOM POSSIBLE CAUSE SOLUTION .Light does not automatically turn on. 1. Circuit breaker is turned off, or fuse is blown. 1. Turn circuit breaker on, or replace fuse.2. Bulb is defective. 2. Replace light bulb.3. Poor connection. 3. Verify all wiring connections.4. Control may be wired incorrectly. 4. Check wiring.5. Daylight sensing prevents lights on 5. Re-adjust daylight sensing level.6. Manual On mode selected 6. Set device to Automatic On mode. .Light does not automatically turn off. 1. Motion is still present. 1. Make sure there is no motion during the time delay period.2. Time Delay has not expired. 2. No action needed or shorten TIME DELAY.3. Control may be wired incorrectly. 3. Check wiring4. Switch is being triggered by air vent or other heat source. 4. Move switch to the other switch location (if a 3-way), or determine thesource triggering the switch, and alter the air flow. .Light does not stay on 1. Motion is not detected. 1. Create movement in front of the sensor for 5 seconds.2. TIME control is set for too short a delay 2. Set switch TIME control to longer time period. .Remote switch does not work 1. Control may be wired incorrectly. 1. Check wiringEATON WIRING DEVICES LIMITED 2 YEAR WARRANTYEaton Wiring Devices (EWD) warrants this device to be free of defects in materials and workmanship in normal use and service for a period of two years from date of original purchase. THIS 2 YEAR LIMITED WARRANTYIS IN LIEU OF ALL OTHER WARRANTIES, OBLIGATIONS, OR LIABILITIES, EXPRESSED OR IMPLIED (INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE THAT IS INDURATION IN EXCESS OF 2 YEARS FROM THE DATE OF ORIGINAL CONSUMER PURCHASE). NO AGENT, REPRESENTATIVE, OR EMPLOYEE OF EWD HAS AUTHORITY TO INCREASE OR ALTER THE OBLIGATIONS OF EWDUNDER THIS WARRANTY.To obtain warranty service for any properly installed EWD device that proves defective in normal use send the defective device prepaid and insured to Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle,Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8.EWD will repair or replace the defective unit, at its option. EWD will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation,alteration, improper maintenance or repair of damage in shipment to EWD.EWD SHALL HAVE NO RESPONSIBILITY FOR INSTALLATION OF THE DEVICE, OR FOR ANY PERSONAL INJURY, PROPERTY DAMAGE, OR ANY SPECIAL, INCIDENTAL,CONTINGENT, OR CONSEQUENTIAL DAMAGES OF ANY KIND, RESULTING FROM DEFECTS IN THE SYSTEM OR FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTYON THIS PRODUCT.Relay OUTRedBlue3-Way TravelerRedBlack TravelerLightFixtureWhiteFirst Location Second LocationNeutral TravelerDIAGRAM 2B: SENSOR IN LOCATION WITH HOT WIRE3-WaySwitchGround120/277VHotBlackGroundBareGreenRelay INOrangeHotBlackWhite120/277VBlack TravelerDIAGRAM 3: SENSORS IN BOTH LOCATIONSLightFixtureRed TravelerWhiteNeutral3-WayBlue3-WayBlueRelay OUTRedBlackRelay OUTRed120/277VGroundBareGreenRelay INOrangeBlack TravelerGroundBareGreenRelay INOrangeHotBlack120/277VHotBlack120/277VHotBlackBlack Traveler1. PRESS TORELEASEHOOKFIGURE 42. LIFT UPBUTTONLIGHT LEVELTEST51030TIME DELAYTURN TO SETFIGURE 5:www.eaton.comwww.eaton.com/wiringdevicesEIS-0156-E (REV.A) |
Related manuals for Eaton OSP10M
Eaton Home Heartbeat Quick Start Manual
Eaton CSAU-01/02 Quick Installation Manual
Eaton 738r Manual
Eaton EAFR-01 User Manual
Eaton Powerware User Manual
Eaton MPD-C-EXT Product Manual
Eaton 50 Series Instruction Manual
Eaton GFX Installation And Operation Manual
Eaton SVPD Series Programming Manual
Eaton WSPS 05 Instruction Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine