INTRODUCTIONPower Xpert 9395 UPS (300 kVA) Installation and Operation Manual 164201728 Rev 2 www.eaton.com/powerquality1-41.2.5 Monitoring and Communication Remote Monitor Panel II (RMP II) – An optional RMP II contains backlit statusindicators and a local horn, allowing monitoring of the operational status and alarmcondition of the UPS from virtually any location within the facility. Relay Interface Module II (RIM II) – An optional RIM II uses relay contact closures toindicate the UPS operating status and alarm condition. Supervisory Contact Module II (SCM II) – An optional SCM II establishes an interfacebetween the UPS system equipment and the customer's monitor. X-Slot Cards – Optional X-Slot cards support several protocols, such as SNMP,HTTP, IBM® AS/400®, and Modbus®. eNotify Remote Monitoring and Diagnostics Service – An optional service that provides24/7 remote monitoring of 43 alarms, temperature/humidity and battery chargeinformation, daily heartbeat check, and monthly report. The service also providescustomer notification of significant alarms, remote diagnostics, and dispatch oftechnicians. A ConnectUPS-X Web/SNMP Card is required in an X-Slotcommunication bay. An optional Environmental Monitoring Probe (EMP) is requiredfor temperature/humidity monitoring.See Chapter 8, “Communication,” for additional information on monitoring andcommunication features.1.3 Basic System ConfigurationsThe following basic UPS system configurations are possible: Single UPS with one UPM and two to four battery cabinets for the UPM Single UPS with one common battery UPM, a common battery FI-UPM, and two tofour battery cabinets for the UPMs Single UPS with one separate battery UPM, a separate battery FI-UPM, and two tothree battery cabinets per UPM Single UPS with one UPM and a standalone battery rack system Single UPS with one common battery UPM, a common battery FI-UPM, and onestandalone battery rack system for the UPMs Single UPS with one separate battery UPM, a separate battery FI-UPM, and onestandalone battery rack system per UPMThe UPS system configuration can be enhanced by adding optional accessories suchas a Remote Emergency Power-off (REPO) control, RMP II, or X-Slot communicationcards.1.4 Using This ManualThis manual describes how to install and operate the Power Xpert 9395 UPS (300kVA) cabinet. Read and understand the procedures described in this manual to ensuretrouble-free installation and operation. In particular, be thoroughly familiar with theREPO procedure (see paragraph 7.3.10 on page 7-16).The information in this manual is divided into sections and chapters. The system,options, and accessories being installed dictate which parts of this manual should beread. At a minimum, Chapters 1 through 4 and Chapter 7 should be examined.Read through each procedure before beginning the procedure. Perform only thoseprocedures that apply to the UPS system being installed or operated.