Eaton Scantronic i-on10 Installation Instructions Manual
Also see for Scantronic i-on10: Configuration guide
ScantronicSpecificationsStandards and ComplianceThe installer must remove or adjust any compliance labelling if anon-compliant configuration is selected.Intrusion compliance: EN 50131-1:2007+A2:2017; EN 50131-3:2009;EN 50131-6:2017+A1:2021; EN 50131-10:2014; EN 50136-2:2013;BS8243:2010; PD6662:2017Security grade: Grade 2.Environmental class: Class II.Protection: IP40, IK06.SecurityAccess codes: 4-digit, giving 10,000 combinations. 6-digit, giving1,000,000 combinations.Code blocking: Blocked for 90 secs after 4 incorrect codes in series.Proximity tag differs: 4,294,967,296.GeneralRelative Humidity: 0 to 93%, non-condensing.Operating temp. range: -10°C to +55°C.Dimensions: 239mm (h) x 250mm (w) x 87mm (d).Weight: 2.8kg (without battery).Case material: Steel.ElectricalThis product complies with the requirements of EN50131-6 Type Apower supply at Grade 2 and environmental class II.Mains power supply: 230Vac + 10%/-15%, 200mA max, 50Hz.Control unit internal mains fuse: T250mA.Control unit power supply: 13.7Vdc, 1.0A max of which 180mA isreserved for battery recharge and 820mA to power the system.Control unit PCB current consumption: 40mA quiescent; 70mA max(in alarm) excluding external devices and battery charging.Standby battery: 12V, 7Ah, sealed lead acid. Min standby time:12hrs. (see “Step 2: Check standby battery capacity”). Max rechargetime: 72 hrs.12V aux: 600mA max*12V bus: 400mA max*12V to plug-by communicator: 400mA max**Maximum current before triggering over-current protection.Output voltage range: 12V outputs are 9.5Vdc to 13.8Vdc.Max p-to-p ripple voltage: 0.5V.Low-battery fault at: <12V.Aux power output fault at: <9V.OP1-3: Open collector transistor, 500mA max.Plug-by outputs: Open collector transistor, 50mA max.Loudspeaker: 12Vdc, 280mA max. Min impedance 16 Ohm.The information, recommendations, descriptions and safety notations in this document arebased on Eaton Corporation’s (“Eaton”) experience and judgment and may not cover allcontingencies. If further information is required, an Eaton sales office should be consulted.Sale of the product shown in this literature is subject to the terms and conditions outlinedin appropriate Eaton selling policies or other contractual agreement between Eaton and thepurchaser.THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED ORIMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE ORMERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTINGCONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIREOBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PARTOF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES.In no event will Eaton be responsible to the purchaser or user in contract, in tort (includingnegligence), strict liability or other-wise for any special, indirect, incidental or consequentialdamage or loss whatsoever, including but not limited to damage or loss of use ofequipment, plant or power system, cost of capital, loss of power, additional expenses inthe use of existing power facilities, or claims against the purchaser or user by its customersresulting from the use of the information, recommendations and descriptions containedherein. The information contained in this manual is subject to change without notice.© 2022 EatonEaton, Security House, Vantage Point Business Village, Mitcheldean, GL17 0SZ.www.myscantronic.comProduct Support (UK) Tel: +44 (0) 1594 541978 available 08:30 to 17:00 Monday to Friday.email: securitytechsupport@eaton.comi-on10 Control UnitInstallation InstructionsThe i-on10 is a 10-zone grade-2-compliant control unit. The i-on10provides a reliable, easy-to-install, wired solution for domestic andsmall commercial applications.Key features• Supports up to 10 wired zones, all provided on-board.• Compatible with a range of wired detectors, including PIR sensorsand door contacts.• Supports up to four keypads connected to the system bus.• Grade 2 compliant.• Support for one full-set level and up to three part-set levels.• Configurable through a keypad.• On-board connections for wired siren/strobe unit.• On-board open-collector output to operate an external auxiliarydevice.• Plug-by communicator port with 8 outputs to communicate withan alarms-receiving centre (requires MISC-COMPACK12 and asuitable standalone communicator, such as 0840UK-21).• Metal case, fitted with a 1A power supply and space for a 12Vdc7Ah backup battery.• Back and lid tamper switches.• Support for up to 10 users.Safety InformationThis product must be installed by qualified service personnel.WARNING: BEFORE INSTALLING THIS EQUIPMENT, ENSURE THATTHE MAINS SUPPLY FOR THE CONTROL UNIT IS DISCONNECTEDAND ISOLATED. All electrical connections must be carried out by aqualified electrician and comply with current local regulations.WARNING: When connected to the mains with power applied, mainsvoltages are present on the shrouded heads of the terminal screwsof the mains connector (Figure 4).WARNING: The mains cable to the control unit must use a double-pole isolation device in accordance with EN 62368-1.WARNING: Good practice requires that documentation is not storedwithin the enclosure.Caution: If you need to handle the PCB in the control unit, takestandard precautions to prevent damage by static electricity.Installing the control unitStep 1: Choose a location for the control unitThe control unit must be located:• Within the protected area (but not in an entry or exit zone).• Out of sight of potential intruders.• Upright (battery at the bottom) on a wall or other flat surface (todiscourage tamper attempts from the rear).Step 2: Check standby battery capacityCheck that the battery is able to power the system for at least 12hours during a mains failure, including two periods of 15 minutes inalarm. This is the minimum period for grade 2 compliance.To do this, you will need to calculate the total current drawnfrom the battery during a mains failure. Please refer to thei-on10Configuration Guide for worked examples.Step 3: Install cablingNote the following (refer to thei-on10 Configuration Guide forguidance):• Normally, standard 7/0.2 un-screened alarm cable is suitable forwiring to keypads and wired siren/strobe units.• Screened cable may be needed if the cable runs near to sourcesof electromagnetic interference.• Keep cables to keypads separate from any other wiring.• You can connect keypads using a daisy-chain (serial) or star(parallel) configuration.• Cables must enter the control unit using the dedicated cable-entryholes (Figure 1).• The maximum length of the cable to keypads depends on anumber of factors, including the number of keypads and whetherdaisy-chain or star connections are used.Step 4: Remove the lid of the control unitRelease the two screws on the front of the lid, then lift it off.Step 5: Mount the control unitMount the control unit in the orientation shown in Figure 1 using thethree fixing holes and minimum 40mm long No8 (4mm) screws. Useonly the designated cable-entry holes.L NMains cableentrySignal cableentryMainsterminalsFixing holesSignal cable entryFigure 1. Fixing holes and cable entriesPart number 14199588Issue 2 24/01/22 |
Related manuals for Eaton Scantronic i-on10
Eaton i-on30R Installation Instructions Manual
Eaton NH00 Installation Instructions Manual
Eaton eNMC2 Installation Instructions Manual
Eaton EOP5T07 Installation Instructions Manual
Eaton NRX Series Installation Instructions Manual
Eaton MEMSHIELD 4 Installation Instructions Manual
Eaton HK-K95-K150 Installation Instructions Manual
Eaton PSG480B24RM Installation Instructions Manual
Eaton Form 4D Recloser Control Installation Instructions Manual
Eaton COOPER POWER Series Installation And Operation Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine