Eaton ePDU G3 Installation & Quick Start Manual
Also see for ePDU G3: Troubleshooting guideInstallation and connection guideOperation manualManualOperating manual
NETWORK CONNECTIVITYNETWORK CONNECTIVITY©Copyright 2014 Eaton, Raleigh NC, USA. All rights reserved. No part of this document may be reproduced in any way without the express written approval of Eaton. • P-164000314_2 • July 2014 • www.eaton.com/powerqualityThe network connection automatically receives an IP address through the Dynamic HostConfiguration Protocol (DHCP) if available on the network. If a DHCP is enabled but a DHCPserver is not available, the eNMC will fall back to the last-used IP address setting. Alternately, it ispossible to set a static IP address by using either the LCD menu or a serial connection commandline interface (CLI).You can also connect up to four ePDUs together using the Daisy Chain port and an RJ-45 split-ter (provided). This enables multiple ePDUs to communicate over one Ethernet port. Refer to theEaton ePDU G3 Operation Manual for detailed instructions. View the operation manual online at:http://www.eaton.com/ePDUNETWORK COMMUNICATION CONFIGURATIONNETWORK COMMUNICATION CONFIGURATIONSSETUP USING THE LCD — STATIC IP ADDRESSETUP USING THE LCD — STATIC IP ADDRESSSSETUP USING A SERIAL CONNECTION — STATIC IP ADDRESSETUP USING A SERIAL CONNECTION — STATIC IP ADDRESS1. The ePDU defaults to DHCP enabled when deliv-ered.2. Connect to a network that has a DHCP server andwait 20 seconds.3. Obtain the IP address from the LCD homescreen.COMMUNICATION MANAGEMENTCOMMUNICATION MANAGEMENTSome Eaton ePDU G3 power distribution products have an internal ePDU NetworkManagement and Control (eNMC) module that manages the ePDU communicationinterfaces. Basic network communication configuration must be performed before theWeb or Command Line Interface (CLI) user interfaces can be accessed and used. Thissheet describes how to set eNMC parameters and enable the module.DiagramReference Description1 Serial or Environmental Monitoring Probe (EMP) Port2Yellow Serial/EMP Port LED: RS-232 Operation and Activity StatusOFF: No EMP connectedFLASHING: EMP connected3Green Serial/EMP Port LED: ePDU Communication StatusOFF: ePDU start-up in progressFLASHING: eNMC module operational4 Ethernet 10/100 Base-T Port5 Green Ethernet Port LED: Operation Transfer Rate StatusOFF: Port operating at 10 Mbits/sON: Port operating at 100 Mbits/s6Yellow Ethernet Port LED: Connection and Transmission Activity StatusOFF: ePDU not connected to the networkON: ePDU connected to the network, but no activityFLASHING: Port is sending or receiving (transmission active)7 Reset ButtonNote: To restart the eNMC, insert a probe and press the button for 3 seconds (or until the LCDgoes blank). This does not reset power to the outlets.8 USB Port: Used for Firmware UpgradeNote: Refer to the Eaton ePDU G3 Operation Manual for more information.9 Daisy Chain Port10Yellow Daisy Chain Port LED: Transmission Activity StatusFLASHING: ePDU is transmitting data11 Green Daisy Chain Port LED: Role Assignment in Communication ProtocolON: DeviceFLASHING: Host87109 112354 61CCOMMUNICATION STATUS LEDSOMMUNICATION STATUS LEDSThe ePDU front panel includes communication and monitoring ports, LED status indica-tors, and operation buttons. The ports and the associated LED indicators are describedin the following table.After establishing a serial connection, perform the following steps:1. In the terminal emulator session window, enter the default user name (admin) at the loginprompt. For example:Enter Login: adminEnter Password:2. Type admin (default) at the password prompt. Press Enter.3. The CLI uses a “get” command to return the value of a setting and a “set” command tochange the value of a setting. For example:PDU#0>set System.Network.DHCP 0PDU#0>get System.Network.DHCP04. Type set System.Network.DHCP 0 and press Enter to modify the value (0 = disabled and1= enabled). For example:PDU#0>set System.Network.DHCP 005. Set the IP address to a value provided by your system administrator.PDU#0>set System.Network.IPAddress xxx.xxx.xxx.xxxxxx.xxx.xxx.xxx6. If necessary, set the network Subnet Mask to the value required by your system administrator.PDU#0>set System.Network.IPMask 255.255.yyy.yyy255.255.yyy.yyy7. Set the network Gateway to the value required by your system administrator.PDU#0>set System.Network.IPGateway zzz.zzz.zzz.zzzzzz.zzz.zzz.zzz8. Wait 10 seconds. Use the reset button to restart the eNMC and apply the new settings.ote:N For alternate instructions to access the CLI using Telnet, refer to the Eaton ePDU G3 Operation Manual. View the operation manual online at: http://www.eaton.com/ePDU.SSETUP USING THE LCD — DHCPETUP USING THE LCD — DHCPEnterEnterESCESCEnterESCIPv4 SettingsDHCPSubnet MaskGatewayIP addressEnterESCMain MenuActive AlarmsAlarms HistoryMeterControlSettingsIP address192 168123123OKSettingsDisplayDaisy ChainLanguageIPv4Clear HistoryUse the RJ45-to-DB9 serial cable that is provided. If your computer does not have a DB9 (RS-232) connector, a USB-to-RS-232 adapter can be purchased separately. Access the CLI using a terminalemulation program such as HyperTerminal®, PuTTY, or TeraTerm. To set up the serial port using your selected terminal emulation program, use the following settings:Bits per second: 9600 Data bits: 8 Parity: None Stop bits: 1 Flow Control: NoneEnterESCEnterESCEnterESCDHCPDisableEnableDisableEnterESCMain MenuActive AlarmsAlarms HistoryMeterControlSettingsIPv4 SettingsIP AddressSubnet MaskGatewayDHCPSettingsDisplayDaisy ChainLanguageIPv4Clear HistoryWait 10 seconds. Use the reset button to restart the eNMC and apply the new settings.14/06/201315:55:26192.168.123.123EMA305-10The default settings are: DHCP: Enabled IP Address: 192.168.123.123 Subnet Mask: 255.255.255.0 Gateway: 192.168.123.1 Username: admin Password: adminGroups of Eaton ePDU G3 models can be configured or updated with new firmware atthe same time using Eaton Intelligent Power Manager (IPM). The IPM software is avail-able separately at no cost for up to 10 devices.Disable DHCPReset and ApplySet theStatic IP Address123 |
Related manuals for Eaton ePDU G3
Eaton ePDU G3HD Quick Start Manual
Eaton NEMA 12 Installation Manual
Eaton EWFFSC15 Quick Start Manual
Eaton CBEU-02/03 Installation Manual
Eaton ePDU G3 Manual
Eaton 11 Series Installation And Start-up Manuallines
Eaton eNMC2 Installation Instructions Manual
Eaton NH00 Installation Instructions Manual
Eaton mMINT Installation And Use Manual
Eaton EOP5T07 Installation Instructions Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine