Water clock2012 Water clock12.1 Inserting the batteries Open the battery compartment (1). Insert two batteries (type AAA). Pay attention to correct polarity of the batteries. Close the battery compartment (1).12.2 Setting the capacity Press and hold down button (2). Press button (3) with a ballpoint pen tip. Release both buttons as soon as “FLI1” flashes in the display. Press button (2) repeatedly until 8000 litres is shown on the display. Press button (3) with a ballpoint pen tip to store the value. “FLI 2” flashes. Shortly thereafter “OFF”. Press button (3) with a ballpoint pen tip to turn off “FLI 2”. Proceed the same way for “FLI3” to “FLI5”.As soon as the set water volume is exceeded, an acoustic signal is triggered. Confirm with button (3) to reset the alarm. Replace the hygiene filter.12.3 Displaying the remaining capacity Press button (2). The remaining water volume is displayed. Press button (2) again. “FLI 1” flashes twice. The remaining capacity is displayed.12.4 ResetAfter replacing the hygiene filter, the consumed amount of water must be reset. Press and hold down button (3) for 8 seconds. An acoustic signal sounds. The consumed water is reset.12.5 Changing the batteriesWeakening batteries are indicated by an acoustic signal. Open the battery compartment (1). Insert two batteries (type AAA). Pay attention to correct polarity of the batteries. Close the battery compartment (1).