Setup and connection6Installation diagram Install the pressure reducer (3) and water clock (5) easily accessible to a wall or in kitchen cabinet. Do notyet plug in any hoses between the components.Item Description1 Water supply (max. 35 °C)2 Reduction 3/4” or 3/8”3 Pressure reducer4 Pressure gauge with T-piece (installed temporarily)5 Water clock6 Acqua 80IMPORTANT: Do not insert the hygiene filter yet. Wash hands, put on protective gloves and spray with EAUVATION N° 2. Connect hoses to all the components. Before inserting the hoses, spray the end of the hoses withEAUVATION N° 2. Do the same for the hose connections of the components.The pressure gauge is removed again later. Therefore, the hose between the pressure gauge and thewater clock must be sufficiently long. Insert the water connection hose into the“FILL THE ICE-BANK” connection. All connectors must be secured with locking clips.Setting the water clock Set 8000 l water volume (12).4.3 Waste waterThe drip tray can be connected to the waste water.Waste water connection requirements: Trap Level lower than the drip tray Hose to the waste water connection has a steady gradient to ensure no backlog of water