Part 10 - Lighting the appliance / First start-upSet the comfort levelSet the maximum central heating temperature1. Press [P3] or [P4]. The maximum CH temperature is shown. The ‘radiator’ symbol is flashing.2. To change the CH temperature:a. Decrease the maximum CH temperature using [P3].b. Increase the maximum CH temperature using [P4]. 3.Press [P2] within 30 seconds to confirm the change.NoticeIn case you wait longer than 30 seconds or in case you press [P1], the adjusted setting will be cancelled.Set the hot water comfortThe hot water can be set to three comfort types:• Eco: The hot water is only heated when there is a hot water demand. The temperature of the DHW heatexchanger is not maintained. This saves energy.• Comfort: the temperature is maintained 24 hours a day, and is checked every hour.• Ecomfort: The thermostat works in the comfort position by day and in the eco position by night (Only incombination with an OpenTherm® room thermostat).1. Press [P5] or [P6] to open the comfort menu. The ‘tap’ symbol in the display is flashing.2. Select the hot water comfort:• Press [P5] to select ‘eco’.• Press [P5] twice to select ‘ecomfort’ (only with OpenTherm® room thermostat).• Press [P6] to select ‘comfort’.• Press [P2] within 30 seconds to confirm the change.NoticeIn case you wait longer than 30 seconds or in case you press [P1], the adjusted setting will be cancelled.56