General recommendations for rack mountingAlthough not required, a 1U space between units makes it easier for you to remove the unit from the rackif that the unit requires service. A 1U space between units also provides additional cable routing options.We recommend 100 mm spacing from the front panel of the unit to the rack front or rack door. This providesenough room for you to route the cables without excessive bending or insulation damage.Caution: To prevent personal injury or damage to the unit, F5 Networks strongly recommends thatat least two people perform the installation.Important: This product is sensitive to electrostatic discharge (ESD). F5 Networks recommends thatyou use proper ESD grounding procedures and equipment when you install or maintain the unit.Components provided with the AC-powered chassisWhen you unpack the VIPRION 2400 AC platform chassis, you should make sure that the followingcomponents are included.HardwareQuantityPower cables (C19 to NEMA 6-20P)2Mounting brackets (pre-installed on chassis)2Four-point rack mounting kit1Cable routing brackets2Cable management covers2Components provided with bladesWhen you unpack a VIPRION B2000 Series blade, you should make sure that the following componentsare included.HardwareQuantityRJ45 to DB9 console port cable (beige)1RJ45F to RJ45M rolled adapter (beige)1SFP+ 10G optical transceivers2Electrical static discharge (ESD) strap124Platform Installation