4Technical DataPhysical dimensions of theoperator caseLength: 7 3/4 in. (195 mm)Width: 5 1/2 in. (140 mm)Height: 11 3/8 in. (290 mm)Power voltage required* 230 VAC, +6 or -10%, 60 Hz*Built-in control panel 746 MPS, 220 VAC ±10%, 50–60 HzAbsorbed power 300 WattsAmperage draw 1.5 ampsHorsepower rating 1/2 hpSpeed of motor rotation 1400 rpmGear ratio 30:1Operating temperature range -13 to 158 deg F (-25 to +70 deg C)Thermal cut out of motor 248 deg F (120 deg C)Weight, including oil 31 lb (14 kg)Oil quantity 2.2 qt (2.1 liters)Oil type FAAC XD 220 or Shell/Tellus #15Gate speed 10 in./sec (25.4 cm/sec)Maximum motor run time** 120 secPulling force*** 35 lb (16 kg)Duty cycles/hour Depends on gate size but the maximummotor run time is 50% at 72 deg F(22 deg C)Maximum amperage draw foraccessories360 mA* Your standard 220 VAC power source meets the specification for 230 VAC, +6or -10%.** If the motor completes its maximum run time, you will have to reset the controlpanel for normal operation.*** The maximum weight pulled at start up assumes nominal voltage (220 VAC) at 72deg F (22 deg C) and assumes the use of high-quality, lubricated bearing rollers on alevel V track.Control PanelYou must install the 746 MPS control panel with the 746Operator. The control panel allows you to set thefollowing operational controls:• Logic: E1, E2, A1, or A2• Pause time: 5, 10, 30, or 120 sec• 5-sec preflashing of attached warning lightIn addition, the control panel allows you to easily definethe direction of the gate’s opening direction for the limitswitch and allows you to control the force of the gate’smovement.Power supply: 220 VACOperating logic: E1, E2, A1, or A2