A11LEDDESCRIPTIONLED STATUSIn BOLD the normal state with gate closed and workingON STEADY OFF BLINKING1 LED BATTERYBoard working on ACpowerBoard working onbattery power or extsupplyBattery charging2 LED +24 Main power present Main power OFF3 LED SET-UPNormal operationSLOW BLINK(1 sec. ON - 1 sec. OFF)SET-UP neededFAST BLINK(0.5 sec. ON - 0.5 sec OFF)SET UP in in progress4 LED ERROR Board malfunction No errors Error conditions. See LED ERRORDISPLAY table5LED BUS_MON Communication onBus “2easy” OKCommunication bus“2Easy” inactive. Verifythe bus “2Easy” devicesfor shortsBus 2Easy devices with theSame address. Verify dip switchSetting on photocells orEncoder LEDs6 LED USBSoftware update doneor USB key not presentUSB key inserted and softwareUpdate in progress(DON’T Remove the USB key)7 RESERVED8LED DL 14OPEN A INPUT (N.O.)OPEN A active OPEN A not activeLED DL 15OPEN B INPUT (N.O.)OPEN B active OPEN B not activeLED DL 16STOP INPUT (N.C.)STOP non active STOP active orwiring errorLED DL 17FSW CL INPUT (N.C.)Closing safetydevices clearClosing safety devicestriggered or wiring errorLED DL 18FSW OP INPUT (N.C.)Opening safetydevices clearOpening safety devicestriggered or wiring error9LED DL 19 FCA1OPEN LIMIT SWITCH MO-TOR1 (N.C.)Limit switchOFF or not used Limit Switch activatedLED DL 20 FCC1CLOSE LIMIT SWITCH MO-TOR1 (N.C.)Limit switchOFF or not used Limit Switch activated10LED DL 21 FCA2OPEN LIMIT SWITCH MO-TOR2 (N.C.)Limit switchOFF or not used Limit Switch activatedLED DL 22 FCC2CLOSE LIMIT SWITCH MO-TOR2 (N.C.)Limit switchOFF or not used Limit Switch activatedA11E024U CONTROL BOARD