26Troubleshooting GA450 V. 2.25.3 Troubleshooting guide5.3.1 Easy-to-solve errors5.3.2 Clamp plate errors5.3.3 Inverter errorsProblem Possible cause Possible solutionThe display shows ‘E00’ Emergency stop is pressed duringidle state.Release the emergency stop. See § 5.4.The display shows ‘E01’ The door is open. Close the door.The display shows ‘E05’ The cradle lock failed to releasethe cradle.Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E08’ Emergency stop is pressed duringrunning state.Release the emergency stop. See § 5.4.The display shows ‘E11’ No can found during clamping orcan is too small.Install a can. See § 3.2.4.Problem Possible cause Possible solutionThe display shows ‘E40’ Home sensor not found. Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E41’ Top of clamp plates is not reachedin time.Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E42’ Clamp plate is sticking on can.Cradle lock is stuck.Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E43’ Clamp plate is stuck in up position.Cradle lock is stuck.Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.Problem Possible cause Possible solutionThe display shows ‘E50’ Inverter is in error mode. Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E51’ Failed to initialize inverter. Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.The display shows ‘E54’ Failed to run the mixer motorforward.Reset the machine. See § 5.4.When the problem persists, contactservice. See § 5.2.