Page 89New Log EventsTwo new log events have been added with the implementation of Point ID these are:-Alarm AbortThe LCD display will show "Alarm Abort" along with the time and date whilst the LEDwill show " AA "Test CallThe LCD display will show "Test Call Sent" along with the time and date whilst the LEDdisplay will show " tC "Access to programming the Point ID event actions is gained through the "ProgramChannels " options. After D1 & D2 and the polarity options have been programmed thefollowing new options will be presented for programming.Note: All these options are defaulted to off and should be turned on asrequired.Set Alrm Unset PA24Hr E/E 12Hr BatTamp AC LF AlertFire W/D DuressZone Remove Alrm-Restore Zone Exclude PA RestoreAC-Restore LF-Restore After AlarmAfter-Alarm Abort-CallIf the After Alarm option is turned on Point ID reports for all options are sentregardless of whether they are turned on or off following the first alarm event. This willcontinue until an Set/Unset event takes place. Note: Alrm=On must be programmed forthis option to work.Note: Options that are turned on will send messages regardless of alarm status.Note: Power-Fail refers to Aux Fuse fail and will reported as Lo-Batt to the centralstation.Note: Part-Sets will be reported as Armed Stay to the central stationNote: Output Module tampers will be reported as Expansion Module Tamper to thecentral station.GardTec 872 Appendix 1