Installation Instructions230/208 VOLT ELECTRICAL CONNECTION OPTIONSHOW TO CONNECT1. Remove the room cabinet.2. Connect to electrical power.3. Review the following steps for applicable supplgvoltages.4. Reinstall the room cabinet.Power cords mag include an arc fault interruptionor a leakage current detection interruption device.A test and reset button is provided on the plug caseor the inline case. The device should be tested ona periodic basis bg first pressing the TESTbuttonand then the RESETbutton. If the TEST button doesnot trip or if the RESETbutton will not stag engaged,discontinue use of the Zoneline and contact aqualified service technician.POWER CORDCONNECTIONA power supplg kit with LCDImust be usedto supplg powerto the Zonelineunit. Theappropriate kit isdetermined bgthe voltage, the means of electrical connection andthe amperage of the branch circuit.Power supply kitConnections of 208 or 230-volt circuits mag be with apower supplg kit or a junction box kit.All wiring, including installation of the receptacle, mustbe in accordance with the NEC and local codes,ordinances and regulations. Codes require the use ofan arc fault or leakage current detection device on thepower cord except direct connect. Be sure to select thecorrect cord for gour installation.db d5 d5Tandem Perpendicular LargeTandem15Amp. 20 Amp. 30 Amp.230/208-voltreceptacleconfiguration.Branch Circuit and Proper GE Power CordUnit Amperage Rating with LCDI Device15 RAK515520 RAK320330 RAK3303**Not approved for use on 7000 BTU models.13ELECTRICAL SUBBASECONNECTION230/208-volt models may be installed using oneof the following electrical subbases:Branch Circuit and Proper GEUnit Amperage Rating Subbase Kit15 RAK204D15P20 RAK204D20P30 RAK204D30P**Not approved for use on 7000 BTUmodels.Electricalsubbases provide an enclosure for directconnection or enclosed receptacles.The subbase kitincludes the power cord.The instructions provided with the selected subbase kitmust be carefully followed. It is the responsibility of theinstaller to ensure the connection of components is donein accordance with these instructions and all electricalcodes.DIRECT CONNECTIONOrder the following Kit for 230/208-volt directconnection as required:Branch Circuit and Power Supply PowerUnit Amperage Rating Accessorg Supply Kit15 RAK4002A RAK415720 RAK4002A RAK420730 RAK4002A RAK4307**Not approved for useon 7000 BTUmodels.Skipto the "HAKE ELECTRICALCONNECTIONTOTHE UNIT"section.