9 SPECIFICATIONSModel : GT5000 GT6000 GT8000 GT10000RatingsPower ratings depending on input voltage : VA / W VA / W VA / W VA / W100V / 200V : 4000 / 3400 4800 / 3400 6400 / 6400 8000 / 6400110V / 220V : 4500 / 3800 5400 / 3800 7200 / 7200 9000 / 7200115V / 230V : 5000 / 4000 6000 / 4200 8000 / 8000 10000 / 8000120V / 208V : 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000120V / 240V : 5000 / 4200 6000 / 4200 8000 / 8000 10000 / 8000127V / 220V : 4800 / 4200 5200 / 4200 8000 / 6900 8700 / 8000Input thermal circuit breaker (A) : 30 30 60 60Internal input fuse 250V, slow (A) : 30 30 30*2 30*2Input converterAC input voltage : Nominal: 120 / 208 VAC input voltage range : 100/(173-200), 110/(190-220), 115/(198-230), 120/(208-240), 127/(220) VInput current waveform : sine waveInput current (A) at nominal input voltage : 20 20 40 40Input power factor : > 0.97Input frequency range : 40 - 70 HzInput phase (L1 to L2) : 120° / 180° / 240° ±10°Inrush current : 40 40 40 40Output converterAC output voltage : 100 / 110 / 115 / 120 / 127 V (selectable)AC output voltage tolerance : L-N ± 3%; L1-L2 ± 5% L-N ± 2%; L1-L2 ± 5%Output frequency : 50 / 60 Hz, auto selectionOutput frequency range : nominal ± 5% with mains synchronizingOutput waveform : sine waveHarmonic distortion : < 3% with linear load, < 5% with non-linear full loadPower factor at nominal input voltage : 0.87 0.8 0.86 0.92Crest factor (peak to RMS current) : ≤ 3 : 1Capacity appliance outlets : with 55A Terminal BlockBypassAC input voltage range : ± 15% of selected output voltageFrequency tracking rate : 1Hz/sFrequency tracking range : ± 5% of selected frequencyTypical transfer time, msec : 0Overload capability : fully protected against overload and short circuitsOverload behavior during battery operation : 130% during 10 seconds 130% during 1 minute: 200% during 2 seconds 200% during 5 secondsOverload behavior during bypass operation : depends on rating of thermal circuit breaker overload protection125% of TCB value for 200 seconds 110% for 300 seconds200% of TCB value for 10 seconds 130% for 30 seconds300% of TCB value for 4 seconds 200% for 5 secondsBatteries (ratings given for 25ºC)Nominal voltage (Vdc) : 144 144 288 288Number / Ah batteries(in battery kit and battery ext. pack) : 12pcs / 8Ah 12pcs / 8Ah 24pcs / 8Ah 24pcs / 8AhType : REW45-12 FRService life : up to 5 years (depending on use)Recharge current : 1 ABattery recharge time(batt. discharged at 100% load) : 6 hours for 90% capacity 3 hours for 90% capacityRuntime in minutesat typical load (75%) : 8 8 9 925% : 31 31 40 4050% : 14 14 16 1675% : 8 8 9 9100% : 5 5 5 5GeneralWeight UPS kg : 30.3 Kg (67 lbs) 49.3 Kg (109 lbs)Dimensions UPS (hxwxd) : 176x430x592 mm (6.9x16.9x22.55 in) 267x430x660 mm (10.5x16.9x26 in)Weight battery pack kg : 43 Kg (94.7 lbs) 91 Kg (200.4 lbs)Dimensions battery pack : 87x430x592 mm (3.47x16.9x2255 in) 173x430x660 mm (6.8x16.9x26 in)Enclosure / protection : steel-plastic / IP20EnvironmentSafety : UL1778Electromagnetic compatibility : EMI: FCC CFR47 Part 15, class A, ESD: IEC61000-4-2, level 4RS: IEC61000-4-3, level 3, EFT: IEC61000-4-4, level 4, Surge: IEC61000-4-5, level 3ANSI C62.41 (IEEE587) Category A (level 3) & B (level 1)Ambient temperature : 0 to +40ºCAudible noise at 1 meter : < 55 dB(A), load and temperature dependentMax. relative humidity : 90% (non-condensing)Color : Black - RAL 9005modifications reserved 41 User manual GT Series 5/6/8/10 kVA UPS 1.0 (US)