MAKING THE CONNECTIONS(cont.)Install 1/2″ flare union adaptor to the1/2″ NPT elbow on pressure regulator.Connect flexible appliance connector toflare union.Move range into approximate positionand connect flexible connector to gassupply line with proper flare unionadaptor.To prevent gas leaks, put a pipe jointsealant or Teflon® tape on all malethreads. NOTE: Make sure sealant or tapeis compatible with Natural and LP gases.When you are finished makingconnections, be sure that all range knobsare turned to OFF before you open themain gas supply valve.WARNING: Do not use a flameto check for gas leaks. Use liquid leak detectorat all joints and connections to check for leaksin the system.JIHGF118Installation InstructionsGAS CONNECTIONSMAKING THE CONNECTIONSInstall a manual shut-off valve in the gassupply line in an easily accessible location.Know how and where to shut off the gassupply to the range.Shut off gas supply before removing anold range. Leave it off until hookup ofnew range is finished.Because solid pipe restricts moving therange, we recommend use of a C.S.A.certified flexible metal applianceconnector.WARNING: Never reuse oldflexible connectors. The use of old flexibleconnectors can cause gas leaks and personalinjury. Always use new flexible connectorswhen installing a gas appliance.Before making gas connections, makesure that the oven shut-off lever (visible atthe back of range) is in the open position.EDCBA113″15″12″31⁄2″7″Gas InletGas supply totop burnerPressureregulator asseen fromfront of rangeGassupplyto ovenOven shut-offlever shown inthe open positionPressureregulatorGassupplyline90° streetelbowShut-off valve Flexible gas line7″ Max.