– 36 –Fault CodesFault Code Description Possible Fixes / Service ChecksSEt Model number not programmed into UI Program model number via service tools.F10~F11 Problem with LED’s on user interface Check Power. Replace UI Board.F61 Cannot communicate with induction modulethat powers left coilsCheck wires connecting UI to inductionTray. Replace UI. Replace induction Tray.F62 Cannot communicate with Induction Modulethat powers right coilsCheck wires connecting UI to inductionTray. Replace UI. Replace induction Tray.F63 Cannot communicate with induction modulethat powers right coilsCheck wires connecting UI to inductionTray. Replace UI. Replace induction Tray.F70~F76 User Interface key fault Clean UI. Cycle power. Replace UI Board.FA0 Fan Harness(is) not connected Check wires connecting UI to InductionTray. Check Fan, UI and induction Tray.Replace fan.FA1 Fan1 is not running at the correct Low speed Check wires connecting UI to InductionTray. Check Fan, UI and induction Tray.Replace fan.FA2 Fan1 is not running at the correct HighspeedCheck wires connecting UI to InductionTray. Check Fan, UI and induction Tray.Replace fan.FA3 Fan2 is not running at the correct Low speed Check wires connecting UI to InductionTray. Check Fan, UI and induction Tray.Replace fan.FA4 Fan2 is not running at the correct HighspeedCheck wires connecting UI to InductionTray. Check Fan, UI and induction Tray.Replace fan.FA5, FA9, FAA Bad coil thermistor reading Check coil thermistor and induction Tray.Replace coil.FA6 Low or high line voltage Check line voltage. Replace Induction Tray.FA7 Missing line frequency Check line voltage/frequency. ReplaceInduction Tray.FA8, FAB Bad induction driver (IGBT) Replace Induction Tray.FAC Induction microprocessor fault Replace Induction Tray.