12DUCTWORK, WIRING LOCATIONSDetermine the exact location of the insertsleeve. Mark the exact centerline location.The ceiling structure must be capable ofsupporting the weight of the insert sleeve(approximately 100 pounds) and anyinadvertent user contact loads.• Measure from the top of the cookingsurface to the bottom edge of the insertsleeve. Add insert sleeve installation height.Mark that location.• Use a level to draw a straight horizontalpencil line on the wall.NOTE: House duct should drop to 11-1/2″above bottom edge of insert sleeve.Location of house duct is importantbecause it must align with vent ofdamper plate assembly.Ceiling ducting:If ductwork will vent straight up to the ceiling:• Use a level to draw a centerline straight upto the ceiling.• On the ceiling, measure 5-1/2″ fromthe back wall to the centerline of an8-1/2″ hole.Wall Ducting:If ductwork will vent to the rear:• Use a level to draw a centerline straightup to the ceiling.• Measure at least 16″ above the pencil linethat indicates the bottom installation height,to the centerline of an 8-1/2″ dia. duct hole.(Hole may be elongated for duct elbow.)HOUSE WIRING LOCATION:• The junction box is located inside the top leftside of the hood.• Wiring should enter the back wall at least15″ above the bottom of the insert sleeve,and within 6″ of the left side of thecenterline.16″ above pencilline indicatingbottom of hood5-1/2″ fromrear wall tocenterline30″ Min.36″ Max.installationheight36″ fromfloor tocountertopWall Installation Preparation30″ Min.36″ Max.installationheight36″ fromfloor tocountertopFront viewSide view11-1/2″4″ liner height11-1/2″16″ above pencilline indicatingbottom of hood4″ liner height PreviousNext |