GAT NET.Lock 7000 SystemElectrical Connectionwww.gantner.com HB_GAT-NETLOCK7000--EN_30 254.3 Connections at the Slave Controller GAT NET.Controller S 70004.3.1 GAT NET.Lock 7000 ConnectionThe locks GAT NET.Lock 7000 are connected via the 4-pin MOLEX connectors on the sockets at the side panel ofthe GAT NET.Controller S 7000.Attention, always use the original cables of GANTNER Electronic GmbH. The connection cable of the lockmust not be modified (shortened or extended). If the cable is too short, only one GANTNER extension cableGAT Net.Lock Cable 4m (partno.: 321826, length = 4 m) may be used. The maximum cable length betweenthe GAT NET.Lock 7000 and the slave controller thus being 8 m.Up to 24 GAT NET.Lock 7000 can be connected to one slave controller. The locks are controlled and differentiatedvia the channel numbers indicated at the side panel of the slave controller. Therefore it is important where the locksare connected and how the locking system is configured.The slave controller should be located in such a manner, that the locks can be connected with the minimum length ofcables (e.g. directly on the lockers).Figure 4.3 - Connection to the GAT NET.Lock 7000 to a slave controller GAT NET.Controller S 7000Note: Do not attempt to connect the RFID locker locks GAT NET.Lock 7000 to a GAT Smart.Controller S 7000 asthis smart controller only operates with GAT Smart.Locks 7001. For the GAT NET.Lock 7000, you have to usethe GAT NET.Controller S 7000 slave controller.4.3.2 Network ConnectionThe slave controllers are interconnected with each other via the serial RS 485 interface. The same RS 485 interfaceis used to connect the slave controllers to a GAT NET.Controller M 7000 master controller.RJ 45 plugs are used for connecting the RS 485 cables at the GAT NET.Controller S 7000. For the network connectionwe recommend to use at least a CAT 5 (STP) cable.Figure 4.4 - RS 485 connection on the GAT NET.Controller S 7000