Part # 4520498 (01/08) Page 5NOTE: The griddle plate may not restevenly on the unit body if the unit isnot properly leveled5 Each caster has a threaded stemto aid in leveling only No castershould be adjusted beyonda maximum of one-half inch,(1/2”/1mm) of exposed threadwith the locking nut tight againstthe stand leg, as shownClearancesThis unit must be installed in accordance with the followingclearances in order to provide proper operation andservicing of the applianceClearances Sides BackLeft RightCombustible 6”(152mm)6”(152mm)6”(152mm)Noncombustible 0” 0” 0”Service Not RequiredType of Floor or Base CombustibleGas Connections1 A readily accessible gas shut-off valve is provided on eachunit, attached to the main manifold under the unit Thegas supply connection must be made with minimum/4 inch NPT pipe Larger than /4 inch (19 mm) supplypipe may be required when a long run of supply pipeis necessary Consult the pipe capacity tables in theinstallation code2 Have a qualified gas technician check the gas pressureto make certain that the existing gas facilities (meter,piping, etc ), will deliver the BTU’s of gas required at theunit, with no more than 1/2 inch (12 mm) water pressuredrop When checking pressure, be certain that all theequipment on the same gas line is turned “ON” The appliance and its individual shut off valve must bedisconnected from the gas supply piping system duringany pressure testing of that system at test pressures inexcess of 1/2 PSIG ( 45 KPA)We suggest installation, maintenance and repairs should beperformed by your local authorized service agency listed inyour information manual pamphletIn the event you have any questions concerning theinstallation, use, care or service of the product, write or callour Product Service DepartmentThis product must be installed by professional personnel asspecified Garland/U S Range products are not approved orauthorized for home or residential use, but are intended forcommercial applications only Garland / U S Range will notprovide service, warranty, maintenance or support of anykind other than for commercial applicationsGeneral InformationDamage Check: check carton or crate for possible damageincurred in shipping After carefully examining, check for“concealed” damage Report any damage immediately toyour carrierLegs, Casters & Leveling1 The unit must be installed on the legs or castersprovided A minimum 4 inch (101 mm) air space mustbe maintained below the unit for required air flow to theburner systems Avoid placing any objects under the unitwhich could obstruct air flow to the burner systems2 For models equipped with casters,the installation shall bemade with a connector that complies with the Standardfor Connectors for Moveable Gas Appliances, ANSIZ21 69/CSA 6 16, Addenda Z21 69B-2006/CSA 6 16B-2006(or latest edition), and a quick-disconnect device thatcomplies with the Standard for Quick Disconnects for Usewith Gas Fuel, ANSI Z21 41/CSA 6 9, Addenda Z21 41A-2005/CSA 6 16A-2005 (or latest edition) Adequate means must be provided to limit movement ofthe appliance without depending on the connector andquick disconnect device or associated piping This canbe accomplished by attaching restraining chains/cablesfrom floor or rear wall to rear of unitEnsure front casters are kept in the locked position exceptwhen the unit must be moved for cleaning or servicing,etc4 When the unit is installed in its operating location, levelthe unit by adjusting the leveling legs Use a level acrossthe front rear, and sides of each unit1/2"(13mm)MAX1/2"(13mm)MAXINSTALLATION Continued