Part # 4523133 Rev 4 (08/04/09) Page 35TROUBLESHOOTINGERROR MESSAGES:NOTE: WE STRONGLY SUGGEST THAT ANY INSTALLATION,MAINTENANCE AND REPAIRS SHOULD BE PERFORMED BYYOUR LOCAL GARLAND AUTHORIZED SERVICE AGENCY.PROBE ERROR:...occurs when the probe is open or not connected. Thecontrol will turn the heat off. If the fault is in the platenthe grill can still be used with recipes that do not call forthe platen. If the grill probe circuit is open, the grill willnot operate. The corresponding tri-color LED will turn redindicating which element is in error. Programming is allowedduring this time.PLATEN DOWN ERROR:...occurs if the platen does not reach the proper position in 40seconds or fails to move during this time. There is an audioalarm with this message.To cancel the message, press .PLATEN UP ERROR:...occurs if the platen is below the lower limit and does notmove for 40 seconds.To cancel the audio alarm press .HEATING ERROR:...occurs when the controller does not detect a propertemperature response over a six minute period. Thecorresponding tri-color LED will turn red indicates whichelement is in error.COMM ERROR:...occurs when there is no communication between thecontrol board and the motor board.Press to reset the message and silence the beep.MOTOR OVER CURRENT:...displayed when the platen has been mechanically resisted.The platen will stop and move to the lower limit. Press theGREEN/CANCEL button to eliminate this display.MOTOR ERROR:...occurs when the platen is going up or down and does notget 5 encoder counts in 1 second when the platen is belowthe lower limit moving down or above the lower limit goingup. At this message the display will flash and there will be anaudio alarm. To cancel the message the power switch mustbe recycled.IGNITION ERROR:...occurs if the ignition feedback signal does not give theproper signal after four tries.FLASHING LED(S):...occurs after a failure for the ignition module to ignitethe gas. The grill LED will flash while the control triesagain. If successful the LED will continue to flash until settemperature is reached and then turn to a solid green.