10This table shows typical connections. OEMs may have a different connection scheme.Connecting high voltage accessories: North American model in.yjWires to connect high voltage accessories must have 0�25” quick-connect terminals�These tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for allconnections, including ground� Depending on where the connections are made on the in�yj pack PCB, 120 V and 240 Vaccessories are supported� Refer to the following tables for correct connections� Note that all female terminals must becorrectly and completely seated on the PCB tab for proper current ratings�Direct outputVoltage 120 V 240 VGreen / ground P27 P27Black / line P25 P25White / common P18 P14Pump 1Voltage 120 V 240 VGreen / ground P28 P28Black / low speed K6-P K6-PRed / high-speed K7-P K7-PWhite / common P19 P15Make sure all accessories are linked to the bonding lug connector located on the side of the spa pack�ConnectionsHeat.wav-yjGreen / ground P5Black / line P3White / common P4Ozone(Working with pump 1 low speed)Voltage 120 V 240 VGreen / ground P30 P30Black / line P23 P23White / common P35 P37Light (12 V DC , 500mA)Switch P33Pump 2 (in.yj-3 only)Voltage 120 V 240 VGreen / ground P29 P29Black / low speed K5-P K5-PWhite / common P20 P16