11Connecting high voltage accessories: European, Australian, New Zealand model in.yj-ceThese tabs require high-voltage accessories to have straight, non-insulated, female quick-connect terminals for allconnections, including ground� Refer to the following tables for correct connections� Note that all female terminals mustbe correctly and completely seated on the PCB tab for proper current ratings�This table shows typical connections. OEMs may have a different connection scheme.Direct outputVoltage 230 VGround P27Line P25Common P18Pump 1Voltage 230 VGround P28Low speed K6-PHigh speed K7-PCommon P19Pump 2 (in.yj-3 only)Voltage 230 VGround P29Low speed K5-PCommon P20Make sure all accessories are linked to the bonding lug connector located on the side of the spa pack�ConnectionsLight (12 V DC , 500mA)Switch P33Heat.wav-yjGreen / ground P5Black / line P3White / common P4Ozone(Working with pump 1 low speed)Voltage 230 VGround P30Line P23Common P35