L NAPCO Security Systems X GEM-P816 Installation InstructionsWI994C 3/04 !Page 15BASIC ZONE CONFIGURATIONThe basic zone configuration for the GEM-P816 is 8 zones. Connect as shown above to terminals 13-24. NormallyClosed (N.C.) devices may be wired in series or Normally Open (N.O.) devices may be wired in parallel. Use the 2.2KOhm end-of-line (E.O.L.) resistor in each zone, if selected in programming (refer to the GEM-P816 ProgrammingInstructions). Zones 1-8 can be selected for a ìFast Loop Response (50 ms)î or a ìNormal Loop Response (750 ms)î.Other zone options include Zone Type (Entry/Exit, Interior, 24 Hour Protection, Trouble and Fire), Instant, Chime, AreaSelection and PGM Output selection. Additional expansion zone modules or wireless sensor transmitters/receivers canbe used to obtain zones numbered 9 through 16.( - )Wiring Connections: Basic Zone Configuration & EZ Zone Doubling Configuration