L NAPCO Security Systems X GEM-P816 Installation InstructionsWI994C 3/04 !Page 45KEYPAD PROGRAMMING MODESKeypad Programming Modes: Function ModeNote:! Functions that are not active, not programmed and/or not applicable to userís area option will be suppressed and will notdisplay.! Due to space constraints, GEM-RP2AS/RP2ASe/RP2ASe2/K2AS messages are abbreviated.! Many functions will not be displayed (such as: ìDISPLAY ZN FAULTSî). It will require a faulted zone to display or the requiredcondition to be present.FUNCTION MODECONDITION DISARMED ARMED KEYPAD MESSAGEIf Zone Faults? * Y N/A DISPLAY ZN FAULTSIf Zone Bypasses? Y Y DISPLAY ZN BYPASSEDAlways * Y Y DISPLAY ZN DIRECTORYIf Fire Alarm? Y Y DISPLAY FIRE ALARMIf Fire Trouble? Y Y DISPLAY FIRE TROUBLEAlways Y N/A ACTIVATE/DEACTIVE CHIMEIf Sensor Watch / If System Trouble? Y Y RESET SYSTEM TRBLAlways N/A N/A ACTIVATE FAULT FINDAfter Test Timer Y Y ACTIVATE DIALER TESTAlways Y N/A TO ARM IN 1-4HRS/PRESS 1-4If Auto Arm? Y N/A TO DELAY AUTO ARM/PRESS 1-4Always Y N/A ACTIVATE PROGRAMAlways Y Y ACTIVATE DOWNLOADFUNCTION MODEPress R buttonRepeatPress Cbutton to Exit at any timeN/A means Not Available.Repeat1 2435 67 8 9 0ABCD EFGNEXT/YESPRIOR/NOAREAScroll DownScroll UpExitYesNoFor "Classic" Keypads1 2435 67 8 9 0ABCD EFGNEXT/YESPRIOR/NOAREAScroll DownScroll UpExitYesNoRFor "K Series" Keypads