Genie Battery Back-Up Installation Instructions Manual
WARNINGCAUTIONNOTE: DO NOT connect the Battery Back-Up Connection Cable to thegarage door opener until you have completed Steps 1 & 2.NOTE: DO NOT REVERSE CONNECTIONS—this WILLdamage the Battery Back-Up Unit.1REQUIREMENTSThis unit is designed to work with specific garage door openers on properlybalanced doors with maximum height of 8 ft. and maximum weight of 500 lb.The unit will provide operation of the door for 24 hours after a power loss.Your garage door opener MUST have the matching Connection Cableconnector in the powerhead.Do not tamper with or rewire Connection Cable.Unit may be wall mounted provided mounting location is within 24 inchesof the powerhead.The unit must be inserted into the mounting bracket as far as it will go, sothat the bracket locks onto the ridges (Figure at Top Right) on top of theBattery Back-Up unit. This prevents the unit from moving.The unit must be mounted so that the Status LEDs are visible from the floor,and it is locked into the mounting bracket.This unit to be used ONLY with Genie® Operator ModelsDisconnect power before performing the following tasks.Do NOT drill holes in the Battery Back-Up case.RIDGES4 SCREWSCOVERMOUNTINGBRACKETLAG SCREWSRAFTERORTRUSSTo Reduce the Risk of Fireor Injury to PersonsTo Prevent possible SeriousInjury or Death by ElectrocutionA. Use only the following type and size battery 12V, 8Ah(Genie® P/N 37342R).B. Do not install Battery Back-up unit on an improperly balanceddoor. An unbalanced door could cause severe injury or damage tothis unit. Repairs and adjustments to the door must be made bytrained service persons using proper tools and instructions.C. Do not dispose of the battery in fire. The cells may explode.Check with local codes for possible disposal instructions.D. Do not open or mutilate the battery. Released electrolyte iscorrosive and candamage eyes or skin. TOXIC if swallowed.E. Exercise care in handling the battery to prevent shorting batterywith conducting materials such as rings, bracelets & keys.F. Change the battery provided with or identified for use withthis product only in accordance with the instructions andlimitations specified in this instruction.G. Observe proper polarity orientation between the battery andchanging circuit.H. Do not set limits while in Battery Back-up Mode. AC powerMUST be connected to the opener, while setting limits, forproper operation.Battery Back-Upfor Residential Garage Door OpenersINSTALLATION INSTRUCTIONS37260500131 01-2013 www.geniecompany.comINSTALLATIONStep 2. MountStep 1. Wire BatteryA.A. Remove Cover (4 screws).— Remove foam shipping block and throw away.C. Replace Cover.B. Connect RED (+) wire to RED terminal,BLACK (–) wire to BLACK terminal.Method 1 - Ceiling MountLocate and attach mounting plate to ceiling rafter ortruss using two 5/16" x 1-3/4" lag screws (provided).— Drill 3/16" pilot holes for lag screws.Rafter or Truss(2) 5/16" x 1-3/4" LagMountingBracketRafter or TrussDrywall(2) 5/16" x 1-3/4" LagMountingBracketcontinued on backTO PREVENT POSSIBLESERIOUS INJURY or DEATHfrom electrocution AND REDUCE RISK of FIRE— Disconnect ALL electric power sources and batterypower BEFORE performing ANY service or maintenance.Install only in DRY locations - NOT INTENDED FOR OUTDOOR USE.For use ONLY with Genie® model Series 30XX or 40XXResidential Garage Door Openers.Use only Genie P/N 37343R for replacement battery.The Genie Model OBB-BXCAUTIONPARA EVITAR POSIBLESLESIONES GRAVES O MUERTEpor electrocución y PARA REDUCIR EL RIESGO DE FUEGO— Desconecte todas las fuentes de energua eléctrica y labatería antes de realizar ningún servicio ni mantenimiento.Instalar sólo en lugares secos — NO ES PARA USO EN EXTERIORES.Para su uso sólo con Genie® modelo de la serie 30XX o40XX abrepuertas residenciales para puertas de garaje.Utilice sólo Genie® P/N 37343R como batería de repuesto.The Genie Model OBB-BXPRECAUCIÓN38310AInstallez uniquement dans des endroits secs — PAS DESTINE A ETREUTILISE EN PLEIN AIR.A utilizer uniquement avec Genie® modèle de la série 30XXou 40XX pour portes de garage résidentielles.Utilisez uniquement des Genie® P/N 37343R commebatterie de replacement.POUR ÉVIER LES BLESSURESGRAVES OU LA MORT parélectrocution et POUR RÉDUIRE ES RISQUES DE FEU— Débranches toutes les sources d’alimentation électriques etla betterie avant toute réparation ou l’entretien.ATTENTION®USThe Genie Modèle OBB-BXPowerMax®, SC, TriloG™, PowerLift™, SilentMax®, CBand IntelliG® that are equipped with Series II electronics.Choose mounting ,Angle Iron Mount and Method 3 - Horizontal Mountand attach the mounting plate using screws provided.Method 1 - Ceiling Mount Method 2 -Disconnect all electric power sources and battery powerBEFORE performing ANY service or maintenance.INSTALL ONLY IN DRY LOCATIONS. NOT FOR OUTDOOR USE.* READ AND FOLLOW ALL SAFETY WARNINGS, CAUTIONSAND THESE ENTIRE INSTRUCTIONS PRIOR TO BEGINNING!MountingPlateConnectionCableBatteryBack-UpTOOLS REQUIREDSockets and RatchetFlat ScrewdriverLag Bolts (shown full size)InstallationInstructionsPARTS INCLUDED7/16 "1/4 "Need help or have questions?DO NOT RETURN to the store.Call us: 800-354-3643 |
Related manuals for Genie Battery Back-Up
Genie SAFE-T-BEAM SYSTEM Installation Instructions Manual
Genie 2042 Installation Manual
Genie GCL-T Installation Manual
Genie GCL-MT Installation Manual
Genie GCL-GH Installation Manual
Genie GCL-GT Installation Manual
Genie GCL-J&H Installation Manual
Genie SCREW DRIVE GARAGE DOOR Installation Instructions Manual
Genie manuals-instructions Support Manuals-instructions
Genie POSTER Assembly/installation Instructions
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine