6.9www.geniecompany.com 03-12Figure 15OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARODC STB ONNOTE: Installation of Series II Monitored Photocells DOES NOT make theynastibihorpyltcirtsynapmoC®eineGehT.esulaitnediserroflageltinu.noitcurtsnocdenozyllaitnediserynanitinulaicremmocafonoitallatsniMonitored Reversing DevicesCALRUNASETCLEARCROLLCALRUNCASCROLLODC Safe-T-Beams® (OPTIONAL)1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.2) Press SCROLL (up or down) until display reads “ODC STB>ON” or“ODC STB>OFF” Figure 15.3) Press SET/CLEAR key to toggle between ON and OFF.4) Press SCROLL (up or down) to shift to a new function and lock setting.5) Press CAL/RUN to return to run mode.WARNING: Photocell systems provideentrapment protection when mounted near the doorwayin such a way that the lower portion of an individuals legwill break the photocell beam during normal walkingthrough the doorway. If an alternative mounting locationis chosen, it must be approved by the facility owner.Heavy Duty OperatorGCL-GHCurrent UL Approved Monitored Reversing Devices1) MillerEdge ME and MT series monitored edge sensors used incombination with Timer-Close Module P/N OPABTCX.S.2) MillerEdge ME and MT series monitored edge sensors used incombination with MillerEdge Signature Module SM-101. (Directconnect through STB inputs).5) NEMA4 Series II Safe-T-Beam®, Monitored Photocells P/N OPAKPEN4GX.S.3) Safe-T-Beam® Monitored Photocells from The Genie® Company, P/N 38176R.4) Series II Safe-T-Beam® Monitored Photocells P/N OPAKPE.S.