WARNING:SCROLL2) Press SCROLL (up or down) until display reads “ODC STB>ON” or6.5OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARODC STB ONNOTE: Installation of Series II Monitored Photocells DOES NOT make the operatorunit legal for residential use.Monitored Reversing DevicesCALRUNSETCLEARSCROLLCALRUNODC Safe-T-Beams® (OPTIONAL)1) If operator is in RUN mode, press CAL/RUN to enter calibration mode.“ODC STB>OFF” Figure 9.3) Press SET/CLEAR key to toggle between ON and OFF.4) Press SCROLL (up or down) to shift to a new function and lock setting.5) Press CAL/RUN to return to run mode.Photocell systems provide entrapmentprotection when mounted near the doorway in such a waythat the lower portion of an individuals leg will break thephotocell beam during normal walking through the doorway.If an alternative mounting location is chosen, it must beapproved by the facility owner.Current UL Approved Monitored Reversing Devices (See page 5.7)1) MillerEdge ME and MT series monitored edge sensors used incombination with Timer-Close Module P/N OPABTCX.S or OPAKMEIX.S INTERFACE MODULE.2) MillerEdge ME and MT series monitored edge sensors (Direct connect through STB inputs).(Direct connect through STB inputs).3) Residential Safe-T-Beam® Monitored Photocells from The Genie® Company,model OSTB-BX (P/N 38176R).4) Monitored Photocells (P/N OPAKPEN4GX.S.).Figure 9www.geniecompany.com 08-12Medium Duty OperatorGCL-MJ&MH