4 - 10 Genie GS-2046 & Genie GS-2646 & Genie GS-3246 Part No. 48339Service Manual - First EditionSection 4 - Scheduled Maintenance ProceduresB-2Inspect the Electrical WiringMaintaining electrical wiring in good condition isessential to safe operation and good machineperformance. Failure to find and replace burnt,chafed, corroded or pinched wires could result inunsafe operating conditions and may causecomponent damage.Electrocution hazard. Contactwith hot or live circuits couldresult in death or serious injury.Remove all rings, watches andother jewelry.1 Inspect the following areas for burnt, chafed,corroded and loose wires:· Ground control panel· Hydraulic power unit module tray· Battery pack module tray· Scissor arms· Platform controls2 Turn the key switch to ground control and pullout the Emergency Stop button to the ONposition.3 Raise the platform approximately 8 feet (2.4 m)from the ground.4 Lift the safety arm, move to the center of thescissor arm and rotate down to a verticalposition.5 Lower the platform onto the safety arm.Crushing hazard. Keep handsclear of the safety arm whenlowering the platform.6 Inspect the center chassis area and scissorarms for burnt, chafed and pinched cables.7 Inspect the following areas for burnt, chafed,corroded, pinched and loose wires:· ECM to platform controls· Power to platform wiring8 Raise the platform and return the safety arm tothe stowed position.9 Lower the platform to the stowed position andturn the machine off.TABLE B PROCEDURES