Part No. 48643 Genie IWP Super Series 11Operator’s ManualSecond Edition • Fourth PrintingMaintenanceObserve and Obey:Only routine maintenance items specified inthis manual shall be performed by the operator.Scheduled maintenance inspections shall becompleted by qualified service technicians,according to the manufacturer's specificationsand the requirements specified in theresponsibilities manual.Maintenance Symbols LegendThe following symbols have beenused in this manual to helpcommunicate the intent of theinstructions. When one or more ofthe symbols appear at thebeginning of a maintenanceprocedure, it conveys the meaningbelow.Indicates that tools will be required toperform this procedure.Indicates that new parts will berequired to perform this procedure.Check the Battery - DC ModelsProper battery condition is essential to goodmachine performance and operational safety.Improper fluid levels or damaged cables andconnections can result in engine componentdamage and hazardous conditions.Electrocution hazard. Contact withhot or live circuits could result indeath or serious injury. Removeall rings, watches and otherjewelry.Bodily injury hazard. Batteriescontain acid. Avoid spilling orcontacting battery acid. Neutralizebattery acid spills with bakingsoda and water.Perform this test after fullycharging the batteries.1 Put on protective clothing and eye wear.2 Remove the battery vent caps.3 Check the battery acid level. If needed,replenish with distilled water to the bottom ofthe battery fill tube. Do not overfill.4 Install the vent caps.