March 2017 Section 5 • SchematicsPart No. 1268494 S-100 • S-105 • S-120 • S-125 5 - 17Genie installed Telematics connector is wried with an Active High digital input.Connector Pin NumberingNote: A Deutsch plug p/n DT06-08SA mates with the Genie Telematics connector.Telematics Connector Pin LegendPin Circuit Type Circuit Properties Genie Machine Function(s) Telematics Use Case1 System Power 12VDC Battery Positive - constant power Supply power to device5 Amp Max. alloweddraw2 System Ground 0VDC Battery Negative Device Ground3 Digital Output 1 12VDC Engine Run Hour Meter Monitor Engine Hours12V = engine run, 0V = engine off4 Digital Output 2 12VDC Key Switch Activation Monitor mechine utilization12V = key switch run, 0V = key switch off5 Digital Output 3 12VDC Foot Switch Monitor mechine utilization12V = active, 0V = inactive6 Digital Input 1 12VDC Remote Disable Engine Start Remotely Prevent Engine Start7* Databus H CAN HIGH Genie Databus J1939 Engine Messages, ReceiveProprietary Genie Telematics Message8* Databus L CAN LOW Genie Databus J1939 Engine Messages, ReceiveProprietary Genie Telematics Message*Tier IV engine models only, J1939 engine message available.*Genie proprietary databus support.Wireless CertificationsTelematic device(s) should comply with specific wireless carrier certifications where applicable andcomply with the following:North America PTCRB, FCC/ICEurope CE, R&TTE